• Curr Med Res Opin · Apr 2009

    In vitro deposition properties of nebulized formoterol fumarate: effect of nebulization time, airflow, volume of fill and nebulizer type.

    • Samuel O Okapo, June Gupta, Eloisa Martinez, and Roach Mark.
    • Department of Analytical Development, Dey LP, 2751 Napa Valley Corporate Drive, Napa, CA 4558, USA. samuel.akapo@dey.com
    • Curr Med Res Opin. 2009 Apr 1; 25 (4): 807-16.

    ObjectiveThe aim of this study was to investigate in vitro the delivery of a new long-acting beta2-agonist (LABA) drug formoterol fumarate inhalation solution (20 microg/2 mL) nebulized with and without ipratropium bromide (0.5 mg/2.5 mL) at different administration times (2.5-22.5 min), airflows (5-28.3 L/min), nebulizer fill volumes (2-6 mL),and nebulizer brands (Pari LC+, Ventstream and DeVilbiss).MethodFormoterol fumarate with and without ipratropium bromide was aerosolized at different administration times, airflows, nebulizer fill volumes, and nebulizer brands. The drug deposited on the throat, filter and stage plates was collected and analyzed by HPLC to determine the aerodynamic profiles of the nebulized drugs under each variable.ResultsIn addition to altering the aerosol characteristics,increasing the nebulizer fill volume including the addition of ipratropium bromide produced a significant(p50.05) increase in the drug output. As expected, sputtering time was significantly longer at low airflows, and vice versa at higher airflows but with a significant loss of drug delivered presumably due to greater solvent evaporation at higher airflows. Airflows between 10 and 28.3 L/min and a nebulization time of approximately 10 min appear sufficient for producing aerosols within the respirable range (1-5 mm MMAD) with the nebulizer/compressor combination used.While the drug output varied significantly (p50.05) among the three brands of nebulizers tested, the LC+ nebulizer appears to produce aerosols (2.7 0.1 microm MMAD) capable of penetrating more deeply into the lung than the other nebulizers evaluated under the current test conditions. This study did not attempt to evaluate different nebulizer/compressor combinations. Also, the cascade impaction data may not necessarily reflect aerosol deposition in the airways in vivo, which may be different depending on the health status of the patient.ConclusionThe results demonstrated that administration of nebulized formoterol fumarate require proper selection of a delivery system/method for safe and effective therapy of the medication with and without ipratropium bromide.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…