• Surgical endoscopy · Aug 2005

    Clinical Trial

    Totally extraperitoneal inguinal hernioplasty with titanium-coated lightweight polypropylene mesh: early results.

    • C Tamme, N Garde, A Klingler, C Hampe, R Wunder, and F Köckerling.
    • Department of Surgery, Center for Minimally Invasive Surgery, Hanover, Hospital, Roesebeckstrasse 15 (Siloah), 30449 Hanover, Germany. c.tamme@chirurgiesiloah.de
    • Surg Endosc. 2005 Aug 1; 19 (8): 1125-9.

    BackgroundThis prospective study of a new titanium-coated low-weight polypropylene (PP) mesh (16 g PP/m2) was designed to investigate the clinical efficacy and safety of totally extraperitoneal endoscopic hernioplasty (TEP).MethodsIn this study, 400 patients (average age, 53.5 years; range, 19-80 years) with a total of 588 inguinal hernias underwent surgery with the TEP technique between September 2002 and October 2003. Of these patients, 12.4% had experienced recurrent hernias after open suture herniotomy. In 92% of the cases (368 patients with 540 hernias), a lightweight (16 g PP/m2) titanium-coated polypropylene mesh was implanted without fixation, and in 8% (32 patients with 48 hernias) an identical medium-weight (35 g PP/m2) mesh was implanted. The first follow-up examination was scheduled for postoperative week 6.ResultsIn the lightweight mesh group, the mean group, operating time per patient was 61 min, corresponding to a calculated time per hernia of 41 min. Two intraoperative major complications occurred: an injury to the cecum and an injury to the bladder. In 12 cases (2%), bleeding from epigastric, testicular, or pubic bone vessels was observed. No injuries to pelvic vessels were seen. One patient was underwent an endoscopic revision to deal with an anticoagulation-related bleed. The mortality rate was 0%. In 12 patients, postoperative hematomas developed. One preperitoneal lipoma had to be extirpated. No infections of the mesh occurred. The median follow-up period for 371 patients (92.3%) was 7.2 weeks (range, 4-14 weeks). These 343 patients (with 504 hernias) had been provided with a lightweight titanium-coated polypropylene mesh (16 g PP/m2) (follow-up rate, 93.2%). Of these patients, 3.5% reported persistent ingunial pain, 1.7% described a sensation of rigidity in the region of the groin, and 3.2% reported dysesthesia. The early recurrence rate was 0.2%.ConclusionsThe TEP procedure can be performed safely and effectively with the appreciably material-reduced and titanium-coated polypropylene mesh without the need for fixation of the implant. The low early recurrence rate of 0.2% is evidence that the posterior wall of the inguinal canal is adequately augmented. The question whether the material reduction and the titanium coating of the mesh may bring about a reduction in postoperative chronic pain and the sensation of rigidity in the inguinal area via an improvement in biocompatibility must await the results of the scheduled follow-up examination 1 year after the surgical procedure.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…