• Respiratory care · Apr 2022

    Mitigating Fugitive Aerosols during Aerosol Delivery via High-Flow Nasal Cannula Devices.

    • Jie Li, A AlolaiwatAmnahADepartment of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois., J HarnoisLaurenLDepartment of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois., James B Fink, and Rajiv Dhand.
    • Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois. Jie_Li@rush.edu.
    • Respir Care. 2022 Apr 1; 67 (4): 404414404-414.

    BackgroundAerosol delivery via high-flow nasal cannula (HFNC) has attracted clinical interest in recent years. However, both HFNC and nebulization are categorized as aerosol-generating procedures (AGPs). In vitro studies raised concerns that AGPs had high transmission risk. Very few in vivo studies examined fugitive aerosols with nebulization via HFNC, and effective methods to mitigate aerosol dispersion are unknown.MethodsTwo HFNC devices (Airvo 2 and Vapotherm) with or without a vibrating mesh nebulizer were compared; HFNC alone, surgical mask over HFNC interface, and HFNC with face tent scavenger were used in a random order for 9 healthy volunteers. Fugitive aerosol concentrations at sizes of 0.3-10.0 μm were continuously measured by particle sizers placed at 1 and 3 ft from participants. On a different day, 6 of the 9 participants received 6 additional nebulizer treatments via vibrating mesh nebulizer or small-volume nebulizer (SVN) with a face mask or a mouthpiece with/without an expiratory filter. In vitro simulation was employed to quantify inhaled dose of albuterol with vibrating mesh nebulizer via Airvo 2 and Vapotherm.ResultsCompared to baseline, neither HFNC device generated higher aerosol concentrations. Compared to HFNC alone, vibrating mesh nebulizer via Airvo 2 generated higher 0.3-1.0 μm particles (all P < .05), but vibrating mesh nebulizer via Vapotherm did not. Concentrations of 1.0-3.0 μm particles with vibrating mesh nebulizer via Airvo 2 were similar with vibrating mesh nebulizer and a mouthpiece/face mask but less than SVN with a mouthpiece/face mask (all P < .05). Placing a surgical mask over HFNC during nebulization reduced 0.5-1.0 μm particles (all P < .05) to levels similar to the use of a nebulizer with mouthpiece and expiratory filter. In vitro the inhaled dose of albuterol with vibrating mesh nebulizer via Airvo 2 was ≥ 6 times higher than vibrating mesh nebulizer via Vapotherm.ConclusionsDuring aerosol delivery via HFNC, Airvo 2 generated higher inhaled dose and consequently higher fugitive aerosols than Vapotherm. Simple measures, such as placing a surgical mask over nasal cannula during nebulization via HFNC, could effectively reduce fugitive aerosol concentrations.Copyright © 2022 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.