• BMC anesthesiology · Nov 2021

    Randomized Controlled Trial Comparative Study

    Intubation using VieScope vs. Video laryngoscopy in full personal protective equipment - a randomized, controlled simulation trial.

    • Hannes Ecker, Simone Kolvenbach, Holger Herff, and Wolfgang A Wetsch.
    • Faculty of Medicine, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
    • BMC Anesthesiol. 2021 Nov 22; 21 (1): 288288.

    BackgroundVieScope is a new type of laryngoscope, with a straight, transparent and illuminated blade, allowing for direct line of sight towards the larynx. In addition, VieScope is disposed of after single patient use, which can avoid cross-contaminations of contagious material. This has gained importance especially when treating patients with highly contagious infectious diseases, such as during the SARS-CoV2 pandemic. In this context, VieScope has not been evaluated yet in a clinical study.Material And MethodsThis study compared intubation with VieScope to video-laryngoscopy (GlideScope) in normal and difficult airway in a standardized airway manikin in a randomized controlled simulation trial. Thirty-five medical specialists were asked to perform endotracheal intubation in full personal protective equipment (PPE). Primary endpoint was correct tube position. First-pass rate (i.e., success rate at the first attempt), time until intubation and time until first correct ventilation were registered as secondary endpoints.ResultsFor correct tracheal tube placement, there was no significant difference between VieScope and GlideScope in normal and difficult airway conditions. VieScope had over 91% fist-pass success rate in normal airway setting. VieScope had a comparable success rate to GlideScope in difficult airway, but had a significantly longer time until intubation and time until ventilation.ConclusionVieScope and GlideScope had high success rates in normal as well as in difficult airway. There was no unrecognized esophageal intubation in either group. Overall time for intubation was longer in the VieScope group, though in an acceptable range given in literature. Results from this simulation study suggest that VieScope may be an acceptable alternative for tracheal intubation in full PPE.Trial RegistrationThe study was registered at the German Clinical Trials Register www.drks.de (Registration date: 09/11/2020; TrialID: DRKS00023406 ).© 2021. The Author(s).

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.