J Magn Reson Imaging · Feb 2017
Effects of arterial transit delay on cerebral blood flow quantification using arterial spin labeling in an elderly cohort.
- Weiying Dai, Tamara Fong, Richard N Jones, Edward Marcantonio, Eva Schmitt, Sharon K Inouye, and David C Alsop.
- Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
- J Magn Reson Imaging. 2017 Feb 1; 45 (2): 472-481.
PurposeTo investigate whether measurement of arterial transit time (ATT) can improve the accuracy of arterial spin labeling (ASL) cerebral blood flow (CBF) quantification in an elderly cohort due to the potentially prolonged ATT in the cohort.Materials And MethodsWe employed a 1-minute, low-resolution (12 mm in-plane), sequential multidelay ATT measurement (both with and without vessel suppression) approach to characterize and correct ATT errors in CBF imaging of an elderly, clinical cohort. In all, 140 nondemented subjects greater than 70 years old were imaged at 3T with a single delay, volumetric continuous ASL sequence and also with the fast ATT measurement method. Nine healthy young subjects (28 ± 6 years old) were also imaged.ResultsATTs measured without vessel suppression (superior frontal: 1.51 ± 0.27 sec) in the elderly were significantly shorter than those with suppression (P < 0.0001). Correction of CBF for ATT significantly increased average CBF in multiple brain regions where ATT was longer than the postlabeling delay (P < 0.01) and decreased intersubject variability of CBF in frontal, parietal, and occipital regions (P < 10-8 ). Measured ATT with vessel suppression was significantly longer in the elderly subjects (eg, superior frontal: 1.76 ± 0.25 sec) compared to the younger adults (superior frontal: 1.59 ± 0.19 sec) in basal ganglia and frontal cortical regions (P < 0.05).ConclusionThe ATT measurement is beneficial for imaging of elderly clinical populations. If ATT mapping is not feasible or available, postlabeling delays of 2-2.3 seconds should be used for elderly populations based on longest measured regional ATTs.Level Of Evidence1 J. Magn. Reson. Imaging 2017;45:472-481.© 2016 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.