• Magn Reson Med · Jan 2015

    New phase-based B1 mapping method using two-dimensional spin-echo imaging with hyperbolic secant pulses.

    • Yoojin Lee, Yeji Han, HyunWook Park, Hidehiro Watanabe, Michael Garwood, and Jang-Yeon Park.
    • Department of Electrical Engineering, Korean Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
    • Magn Reson Med. 2015 Jan 1; 73 (1): 170-81.

    PurposeTo propose a new phase-based B1-mapping method that exploits phase information created by hyperbolic secant (HS) pulses in conventional 2D spin-echo imaging.MethodsIn this B1-mapping method, HS pulses are used to accomplish π/2 excitation and π refocusing in standard multislice spin-echo imaging. When setting the ratio of pulse lengths of the π/2 and π HS pulses to 2:1, the spin-echo phase is independent of offset frequency and varies as a function of B1 strength. To eliminate undesired phase accumulations induced by unknown factors other than the B1 strength, two spin-echo images are acquired using HS pulses applied with opposite frequency-sweep directions, and the resulting phase images are subtracted from each other. To demonstrate the performance of the proposed method, phantom and in vivo experiments were performed using a surface coil and a volume coil.ResultsThe B1 maps obtained by using the proposed method were in accordance with the B1 maps obtained using previous methods in both phantom and in vivo experiments.ConclusionThe proposed method is easy to implement without any sequence modification, is insensitive to B0 inhomogeneity and chemical shift, and is robust in a reasonably wide range of B1 field strength.© 2014 Wiley Periodicals, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…