    Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight.

    • Daniele Andreini, Saima Mushtaq, Edoardo Conte, Chiara Segurini, Marco Guglielmo, Maria Petullà, Valentina Volpato, Andrea Annoni, Andrea Baggiano, Alberto Formenti, Antonio L Bartorelli, Cesare Fiorentini, and Mauro Pepi.
    • Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Clinical Sciences and Community Health, Cardiovascular Section, University of Milan, Milan, Italy. Electronic address: daniele.andreini@ccfm.it.
    • J Cardiovasc Comput Tomogr. 2016 Jul 1; 10 (4): 322-6.

    BackgroundCoronary CT angiography (CTA) is gaining widespread acceptance for the non-invasive evaluation of coronary arteries. However, radiation exposure and administration of iodinated contrast agents are still reasons of some concern. The 80 kV tube voltage increases the attenuation of iodine, allowing to use lower iodine concentration contrast agents for coronary CTA.ObjectiveWe evaluated the diagnostic accuracy of coronary CTA performed with 64-slice scanner, 80 kV tube voltage, iterative reconstruction algorithm and ultra-low concentration contrast medium to reduce iodine load and radiation dose.MethodsWe enrolled 45 patients with low body weight and indication for elective invasive coronary angiography (ICA). All patients received an 80 ml bolus of Iodixanol-270 at an infusion rate of 5 mL/s and underwent coronary CTA (80 kV and 500-550 mA) with prospective ECG-triggering. Image quality score, type of artifacts, coronary CTA evaluability, diagnostic accuracy and radiation exposure were assessed.ResultsPre-test probability of CAD was low-to-intermediate (48%). Accordingly, the prevalence of obstructive CAD was 47% (21 out of 45 patients). Most (93%) of the patients were pre-treated with intravenous metoprolol before scanning and achieved a heart rate suitable for prospective ECG-triggering coronary CTA (53 ± 3 bpm). The mean effective dose and iodine load were 1.1 ± 0.4 mSv and 21.6 gI, respectively. We rated 443 out of 720 coronary segments as being of excellent image quality. In a segment-based model, coronary evaluability (number of coronary segments evaluable/total number of coronary segments), was 97% (699/720 segments). In a segment-based analysis, sensitivity, specificity, positive predictive value, negative predictive value and accuracy for >50% coronary stenosis identification vs. ICA were 89%, 99%, 89%, 99% and 99%, respectively. In a patient-based analysis, sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 94%, 89%, 83%, 96% and 91%, respectively.ConclusionsIn patients with low body weight, image quality and diagnostic accuracy of ultra-low radiation dose and low-iodine load coronary CTA are good and similar to values reported in the literature for standard tube voltage and iodine load protocols.Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.