• Magn Reson Med · Feb 2014

    3D myocardial T1 mapping at 3T using variable flip angle method: pilot study.

    • Hélène Clique, Hai-Ling Margaret Cheng, Pierre-Yves Marie, Jacques Felblinger, and Marine Beaumont.
    • Université de Lorraine, IADI, UMR S 947, Nancy, France; INSERM, IADI, U947, Nancy, France.
    • Magn Reson Med. 2014 Feb 1; 71 (2): 823-9.

    PurposeMyocardial T1 mapping is an emerging technique that could improve cardiovascular magnetic resonance diagnostic accuracy. In this study, a variable flip angle approach with B1 correction is proposed at 3T on the myocardium, employing standard 3D spoiled fast gradient echo and echo planar imaging sequences.MethodsThe method was tested on phantoms to determine the set of standard 3D spoiled fast gradient echo angles adapted to myocardial T1 measurements and was compared to the inversion-recovery spin-echo reference T1 method. Seven volunteers underwent magnetic imaging resonance to acquire myocardial T1 maps and T1 values of the human heart.ResultsThis original method demonstrated good reproducibility in phantoms and a significant correlation between variable flip angle T1 values and reference inversion-recovery spin-echo T1 values. It yielded myocardial T1 values consistent with expected T1 and an increasing homogenization of myocardial segments owing to B1 correction. The mean myocardial T1 value was 1341 ± 42 ms.ConclusionMyocardial 3D T1 mapping using the variable flip angle approach can potentially be useful for evaluating fibrosis on the entire myocardium using a standard clinical sequence.Copyright © 2013 Wiley Periodicals, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…