Pleural Pressure and Optimal Positive End-Expiratory Pressure Based on Esophageal Pressure Versus Chest Wall Elastance: Incompatible Results.
- Gaurav Gulati, Aileen Novero, Stephen H Loring, and Daniel Talmor.
- All authors: Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA.
- Crit. Care Med.. 2013 Jun 12.
Objective1) To compare two published methods for estimating pleural pressure, one based on directly measured esophageal pressure and the other based on chest wall elastance. 2) To evaluate the agreement between two published positive end-expiratory pressure optimization strategies based on these methods, one targeting an end-expiratory esophageal pressure-based transpulmonary pressure of 0 cm H2O and the other targeting an end-inspiratory elastance-based transpulmonary pressure of 26 cm H2O. DESIGN:: Retrospective study using clinical data. SETTING:: Medical and surgical ICUs. PATIENTS:: Sixty-four patients mechanically ventilated for acute respiratory failure with esophageal balloons placed for clinical management. MethodsEsophageal pressure and chest wall elastance-based methods for estimating pleural pressure and setting positive end-expiratory pressure were retrospectively applied to each of 64 patients. In patients who were ventilated at two positive end-expiratory pressure levels, chest wall and respiratory system elastances were calculated at each positive end-expiratory pressure level. MEASUREMENTS AND MAIN ResultsThe pleural pressure estimates using both methods were discordant and differed by as much as 10 cm H2O for a given patient. The two positive end-expiratory pressure optimization strategies recommended positive end-expiratory pressure changes in opposite directions in % of patients. The ideal positive end-expiratory pressure levels recommended by the two methods for each patient were discordant and uncorrelated (R = 0.05). Chest wall and respiratory system elastances increased with increases in positive end-expiratory pressure in patients with positive end-expiratory esophageal pressure-based transpulmonary pressures (p < 0.05). ConclusionsEsophageal pressure and chest wall elastance-based methods for estimating pleural pressure do not yield similar results. The strategies of targeting an end-expiratory esophageal pressure-based transpulmonary pressure of 0 cm H2O and targeting an end-inspiratory elastance-based transpulmonary pressure of 26 cm H2O cannot be considered interchangeable. Finally, chest wall and respiratory system elastances may vary unpredictably with changes in positive end-expiratory pressure. (Crit Care Med 201;41:0-0).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.