    ObjectiveTransit-time flow measurement (TTFM) is the most widely used method for intra-operative graft quality control in coronary artery bypass surgery. Although it may provide the opportunity for the surgeon to promptly revise the graft before the patient is discharged from the operating room, controlled clinical data on the ultimate usefulness of the TTFM are scarce. Clear cut-off values for when to revise grafts have not been set.MethodsA total of 204 consecutive grafts (left internal mammary artery (n=46), vein graft (n=155), and radial artery (n=3)) underwent TTFM in 75 elective coronary artery bypass grafting (CABG) patients. The following parameters were recorded: mean graft flow (MGF), pulsatility index (PI), and insufficiency ratio (IR). After a mean follow-up of 199 ± 42 days, coronary angiography was performed for assessment of graft patency.ResultsA total of 166 grafts were found to be patent (85%), and 29 (15%) were completely occluded. The median and interquartile range (IQR) of MGF for the occluded grafts at the time of surgery was 38 ml min(-1) (IQR, 2549 ml min(-1)) and for the patent grafts 45 ml min(-1) (IQR, 31-71 ml min(-1); p=ns]. The corresponding PI values were 3.3 (IQR, 2.8-5.0) and 2.2 (IQR, 1.7-3.2; p=0.003), and the IR values were 1.6 (IQR, 0.6-6.1) and 0.2 (IQR, 0-2.2; p=0.03). By receiver operating characteristic (ROC) analysis, the highest sensitivity (72%) and specificity (70%) were associated with a PI value>3.0. However, 49 out of 70 such grafts (70%) were found to be patent. Furthermore, 10 out of 16 (63%) grafts, that had a combination of low flow (MGF<15 ml min(-1)) and high PI (>3.0), were patent at control angiography.ConclusionsTTFM predicts graft failure within the 6 months after CABG. However, specific cut-off recommendations for when to revise a graft cannot be set on the basis of TTFM. The cut-off values suggested in the literature lead to unnecessary graft revisions in the majority of cases, and, on the other hand, many technical defects probably remain unnoticed. Better methods to assess the quality of coronary artery bypass grafts are needed.Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.