    Biomechanical Effects of a Dynamic Topping off Instrumentation in a Long Rigid Pedicle Screw Construct.

    • Michael Reichl, Rebecca A Kueny, Reza Danyali, Peter Obid, Hüseyin Übeyli, Klaus Püschel, Michael M Morlock, Gerd Huber, Thomas Niemeyer, and Alexander Richter.
    • *Spine Center, Asklepios Klinik St. Georg †Institute of Biomechanics, TUHH Hamburg University of Technology ‡Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
    • Clin Spine Surg. 2017 May 1; 30 (4): E440-E447.

    Study DesignBiomechanical ex vivo study.ObjectiveTo determine if topping off instrumentation can reduce the hypermobility in the adjacent segments when compared with the classic rigid spinal instrumentation.Summary Of The Background DataLong rigid instrumentation might increase the mechanical load in the adjacent segments, the resulting hypermobility, and the risk for adjacent segment disease. Topping off instrumentation intends to reduce the hypermobility at the adjacent level by more evenly distributing segmental motion and, thereby, potentially mitigating adjacent level disease.Materials And MethodsEight human spines (Th12-L5) were divided into 2 groups. In the rigid group, a 3-segment metal rod instrumentation (L2-L5) was performed. The hybrid group included a 2-segment metal rod instrumentation (L3-L5) with a dynamic topping off instrumentation (L2-L3). Each specimen was tested consecutively in 3 different configurations: native (N=8), 2-segment rod instrumentation (L3-L5, N=8), 3-segment instrumentation (rigid: N=4, hybrid: N=4). For each configuration the range of motion (ROM) of the whole spine and each level was measured by a motion capture system during 5 cycles of extension-flexion (angle controlled to ±5 degrees, 0.1 Hz frequency, no preload).ResultsIn comparison with the intact spine, both the rigid 3-segment instrumentation and the hybrid instrumentation significantly reduced the ROM in the instrumented segments (L2-L5) while increasing the movement in the adjacent segment L1-L2 (P=0.002, η=0.82) and in Th12-L1 (P<0.001, η=0.90). There were no ROM differences between the rigid and hybrid instrumentation in all segments.ConclusionsIntroducing the dynamic topping off did not impart any significant difference in the segmental motion when compared with the rigid instrumentation. Therefore, the current biomechanical study could not show a benefit of using this specific topping off instrumentation to solve the problem of adjacent segment disease.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.