    Sustained accuracy improvement in intraocular lens power calculation with the application of quality control circle.

    • Lei Lin, Pingjun Chang, Jialu Xie, Zhangliang Li, Hongfang Zhang, Fan Lu, and Yun-E Zhao.
    • School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.
    • Sci Rep. 2017 Nov 1; 7 (1): 14852.

    AbstractAccurate intraocular lens (IOL) power calculation is always a challenge in ophthalmology, and unoptimized process may lead to inaccurate refractive outcomes. Quality control circle (QCC) has shown its success in many fields as a process management tool. However, its efficacy in ophthalmology remains unclear. Here we utilized the QCC method to optimize the process and evaluate its efficacy in improving the accuracy of IOL power calculation. After the QCC application, the percentage of eyes with achieved refractive outcomes within 0.5 diopter significantly increased from 63.2% to 80.8% calculated by Haigis formula and 59.2% to 75.8% by SRK/T formula in patients with normal axial length (AL) (22 mm ≤ AL < 26 mm). Although there were no statistically significant differences in patients with long AL by the two formulas (p = 0.886 and 0.726), we achieved an accuracy of 75% with the application of the PhacoOptics software, which was significantly higher than that using the other two formulas (p < 0.001). Our findings indicated that QCC optimized and standardized the process of IOL power calculation, thus improved the accuracy of IOL power calculation in patients who underwent cataract surgery.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…