• Spine J · Jan 2013

    Comparative Study

    Comparison of the biomechanical effect of pedicle-based dynamic stabilization: a study using finite element analysis.

    • Tae-Ahn Jahng, Young Eun Kim, and Kyung Yun Moon.
    • Department of Neurosurgery, Seoul National University, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 464-707, Korea.
    • Spine J. 2013 Jan 1; 13 (1): 85-94.

    Background ContextRecently, nonfusion pedicle-based dynamic stabilization systems (PBDSs) have been developed and used in the management of degenerative lumbar spinal diseases. Still effects on spinal kinematics and clinical effects are controversial. Little biomechanical information exists for providing biomechanical characteristics of pedicle-based dynamic stabilization according to the PBDS design before clinical implementation.PurposeTo investigate the effects of implanting PBDSs into the spinal functional unit and elucidate the differences in biomechanical characteristics according to different materials and design.Study DesignThe biomechanical effects of implantation of PBDS were investigated using the nonlinear three-dimensional finite element model of L4-L5.MethodsAn already validated three-dimensional, intact osteoligamentous L4-L5 finite element model was modified to incorporate the insertion of pedicle screws. The implanted models were constructed after modifying the intact model to simulate postoperative changes using four different fixation systems. Four models instrumented with PBDS (Dynesys, NFlex, and polyetheretherketone [PEEK]) and rigid fixation systems (conventional titanium rod) were developed for comparison. The instrumented models were compared with those of the intact and rigid fixation model. Range of motion (ROM) in three motion planes, center of rotation (COR), force on the facet joint, and von Mises stress distribution on the vertebral body and implants with flexion-extension were compared among the models.ResultsSimulated results demonstrated that implanted segments with PBDSs have limited ROM when compared with the intact spine. Flexion motion was the most limited, and axial rotation was the least limited, after device implantation. Among the PBDS selected in this analysis, the NFlex system had the closest instantaneous COR compared with the intact model and a higher ROM compared with other PBDS. Contact force on the facet joint in extension increased with an increase of moment in Dynesys and NFlex; however, the rigid or PEEK rod fixation revealed no facet contact force.ConclusionsImplanted segments with PBDSs have limited ROM when compared with the intact spine. Center of rotation and stress distribution differed according to the design and materials used. These biomechanical effects produced a nonphysiological stress on the functional spinal unit when they were implanted. The biomechanical effects of current PBDSs should be carefully considered before clinical implementation.Copyright © 2013 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.