-
- Camilo A Molina, Frank M Phillips, Matthew W Colman, Wilson Z Ray, Majid Khan, Emanuele Orru', Kornelis Poelstra, and Larry Khoo.
- 1Department of Neurosurgery, Washington University School of Medicine in St. Louis, Missouri.
- J Neurosurg Spine. 2020 Oct 30: 1-9.
ObjectiveAugmented reality-mediated spine surgery (ARMSS) is a minimally invasive novel technology that has the potential to increase the efficiency, accuracy, and safety of conventional percutaneous pedicle screw insertion methods. Visual 3D spinal anatomical and 2D navigation images are directly projected onto the operator's retina and superimposed over the surgical field, eliminating field of vision and attention shift to a remote display. The objective of this cadaveric study was to assess the accuracy and precision of percutaneous ARMSS pedicle implant insertion.MethodsInstrumentation was placed in 5 cadaveric torsos via ARMSS with the xvision augmented reality head-mounted display (AR-HMD) platform at levels ranging from T5 to S1 for a total of 113 total implants (93 pedicle screws and 20 Jamshidi needles). Postprocedural CT scans were graded by two independent neuroradiologists using the Gertzbein-Robbins scale (grades A-E) for clinical accuracy. Technical precision was calculated using superimposition analysis employing the Medical Image Interaction Toolkit to yield angular trajectory (°) and linear screw tip (mm) deviation from the virtual pedicle screw position compared with the actual pedicle screw position on postprocedural CT imaging.ResultsThe overall implant insertion clinical accuracy achieved was 99.1%. Lumbosacral and thoracic clinical accuracies were 100% and 98.2%, respectively. Specifically, among all implants inserted, 112 were noted to be Gertzbein-Robbins grade A or B (99.12%), with only 1 medial Gertzbein-Robbins grade C breach (> 2-mm pedicle breach) in a thoracic pedicle at T9. Precision analysis of the inserted pedicle screws yielded a mean screw tip linear deviation of 1.98 mm (99% CI 1.74-2.22 mm) and a mean angular error of 1.29° (99% CI 1.11°-1.46°) from the projected trajectory. These data compare favorably with data from existing navigation platforms and regulatory precision requirements mandating that linear and angular deviation be less than 3 mm (p < 0.01) and 3° (p < 0.01), respectively.ConclusionsPercutaneous ARMSS pedicle implant insertion is a technically feasible, accurate, and highly precise method.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.