-
J Clin Orthop Trauma · Sep 2020
Axis vertebral dimensions for safe screw placement: A CT normative data analysis.
- Vibisha Pragash, Balaji Douraiswami, and Suresh Subramani.
- SRM Medical College & Research Centre, Chennai, 603 203, India.
- J Clin Orthop Trauma. 2020 Sep 1; 11 (5): 871-875.
IntroductionMorphometric evaluation of the pedicle and isthmus of second cervical vertebra (C2) (Axis) is extremely vital before contemplating any surgical stabilization involving the Craniovertebral region, in view of its proximity to the vertebral artery and the cervical nerve root. The dimensions of pedicles and isthmuses in C2 vary between individuals and there is paucity of data in the Indian population. This study strives to measure the average pedicle and isthmus dimensions in a sample of population, which would enable selection of screws with safest diameters to be used in C2; thereby avoiding injury to adjacent neurovascular structures.Materials And MethodsOne Hundred patients in the age group between 18 and 70 years who underwent CT scan of head and neck region were included in the study. The aim of this study was to assess the anatomic suitability of transarticular and pedicle screw placement in Axis vertebrae of Indian population and determine the maximum safe diameter for screw placement. The following parameters were measured in millimeters: Pedicle width, Pedicle angle, Internal height and Isthmic height.ResultsThe Mean maximum diameter of potential pedicle screw was 4.99 ± 1.1 mm for the right side with the left side being slightly wider at 5.20 ± 1.16 mm. Twenty eight (28%; 56 out of 200 pedicles) had a measurement < 4.5 mm. The internal height in sagittal images representing the pedicle height was found to be 4.79 ± 0.96 mm on the right side and 4.75 ± 1.04 mm on the left side. Sixty five (65) out of 200 pedicles (32.5%) had measurements < 4.5 mm in sagittal plane. The Mean maximum diameter of potential Transarticular screw (outer diameter of isthmus) was 5.05 ± 0.78 mm for the right side and 5.18 ± 0.84 mm on the left side.DiscussionIsthmic height < 4.5 mm could potentially violate the vertebral foramen when a 3.5 mm screw is used. In our study 22.5% isthmuses were narrow (<4.5 mm). The mean maximum safe diameter for a potential transarticular screw in the present study was 5.11 mm. Though our patients had smaller isthmus dimensions compared with literature, 77.5% of C2 could take a 4 mm transarticular screw quite comfortably considering the 0.5 mm margin on either side. In the present study, 28% of pedicles were found to be inappropriately sized (<4.5 mm) to accommodate the standard 3.5 mm screw. The mean maximum diameter of a potential pedicle screw in our study was 5.09 mm; and in 72% of patients a 4 mm screw could be placed with confidence. Though our patients on an average can accommodate a 4 mm screw comfortably, we suggest a protocol of obtaining CT measurements of C2 prior to operative intervention for identifying those individuals at risk of neurovascular injury; 22.5% for transarticular screw and 28% for pedicle screw.© 2020 Delhi Orthopedic Association. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.