-
- Runlei Ma, Daan Ties, Marly van Assen, Gert Jan Pelgrim, Grigory Sidorenkov, van OoijenPeter M APMADepartment of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.Data Science Center in Health, University of Groningen, University Medical Center Groningen, Groningen, the Ne, Pim van der Harst, Randy van Dijk, and Rozemarijn Vliegenthart.
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713, GZ, Groningen, the Netherlands.
- Eur Radiol. 2020 Dec 1; 30 (12): 6838-6846.
ObjectivesTo determine normal pericoronary adipose tissue mean attenuation (PCATMA) values for left the anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) in patients without plaques on coronary CT angiography (cCTA), taking into account tube voltage influence.MethodsThis retrospective study included 192 patients (76 (39.6%) men; median age 49 years (range, 19-79)) who underwent cCTA with third-generation dual-source CT for the suspicion of CAD between 2015 and 2017. We selected patients without plaque on cCTA. PCATMA was measured semi-automatically on cCTA images in the proximal segment of the three main coronary arteries with 10 mm length. Paired t-testing was used to compare PCATMA between combinations of two coronary arteries within each patient, and one-way ANOVA testing was used to compare PCATMA in different kV groups.ResultsThe overall mean ± standard deviation (SD) PCATMA was - 90.3 ± 11.1 HU. PCATMA in men was higher than that in women: - 88.5 ± 10.5 HU versus - 91.5 ± 11.3 HU (p = 0.001). PCATMA of LAD, LCX, and RCA was - 92.4 ± 11.6 HU, - 88.4 ± 9.9 HU, and - 90.2 ± 11.4 HU, respectively. Pairwise comparison of the arteries showed significant difference in PCATMA: LAD and LCX (p < 0.001), LAD and RCA (p = 0.009), LCX and RCA (p = 0.033). PCATMA of the 70 kV, 80 kV, 90 kV, 100 kV, and 120 kV groups was - 95.6 ± 9.6 HU, - 90.2 ± 11.5 HU, - 87.3 ± 9.9 HU, - 82.7 ± 6.2 HU, and - 79.3 ± 6.8 HU, respectively (p < 0.001).ConclusionsIn patients without plaque on cCTA, PCATMA varied by tube voltage, with minor differences in PCATMA between coronary arteries (LAD, LCX, RCA). PCATMA values need to be interpreted taking into account tube voltage setting.Key Points• In patients without plaque on cCTA, PCATMA differs slightly by coronary artery (LAD, LCX, RCA). • Tube voltage of cCTA affects PCATMA measurement, with mean PCATMA increasing linearly with increasing kV. • For longitudinal cCTA analysis of PCATMA , the use of equal kV setting is strongly recommended.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.