-
Comparative Study
Comparison of Ultrasound-Guided to Fluoroscopy-Guided Biceps Tendon Sheath Therapeutic Injection.
- Jonelle Petscavage-Thomas and Cristy Gustas.
- Department of Radiology, Penn State Hershey Medical Center, Hershey, Pennsylvania USA jthomas5@hmc.psu.edu.
- J Ultrasound Med. 2016 Oct 1; 35 (10): 2217-21.
ObjectivesBiceps tendinitis is a source of anterior shoulder pain and is amenable to therapeutic injection. Studies have shown greater accuracy with image-guided compared to unguided injection of the biceps tendon sheath. There is no literature comparing ultrasound-guided to fluoroscopy-guided biceps tendon sheath injection. The purpose of this study was to compare clinical outcomes, complication rates, procedure success rates, and financial costs of the two imaging-guided methods.MethodsA 10-year retrospective review of the picture archiving and communication system was performed to identify patients who underwent image-guided proximal biceps tendon sheath injection. Two radiologists reviewed the picture archiving and communication system and clinical notes to record pain relief, complications, fluoroscopy time, first-pass success rate (defined as injection into the sheath on the first needle pass), final success rate (needle placement in the tendon sheath on the final needle pass), and average costs.ResultsFifty fluoroscopy-guided and 53 ultrasound-guided cases were identified. There was no statistically significant difference in pain relief or complications. The first-pass success rate was 90.6% for ultrasound compared to 74.0% for fluoroscopy. The final-pass success rate was 98.2% for ultrasound versus 92.0% for fluoroscopy. The mean fluoroscopy time was 57.6 seconds. Ultrasound showed preinjection abnormalities of the biceps tendon in 47.5% of cases.ConclusionsCompared to fluoroscopy-guided biceps tendon sheath injection, ultrasound had higher initial- and final-pass success rates, visualized abnormalities before injection, and had similar pain relief and complication rates. Ultrasound is more accurate and has greater diagnostic benefits than unguided or fluoroscopy-guided biceps tendon sheath injection.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.