- Helen Anwander, Livia Büchel, Fabian Krause, Klaus Siebenrock, and Timo Schmid.
- Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Switzerland. Electronic address: Helen.anwander@insel.ch.
- Injury. 2022 Feb 1; 53 (2): 719-723.
IntroductionCompression sonography has been introduced for non-invasive measurement of compartment compressibility and possible diagnostic tool for acute or chronic compartment syndrome in studies using human cadavers and animal models. To date, standard values in healthy subjects are not yet defined. The aim was to define standard compartment compressibility values in healthy human subjects and to assess the reliability of this measurement method.MethodsIn 60 healthy volunteers, using ultrasound, the diameter of the tibial anterior compartment was measured while applying no pressure, 10mbar and 80mbar of external pressure. A pressure manometer on the ultrasound head was used to monitor the externally applied pressure. Compartment compressibility ratio (R0-80, respectively R10-80) was calculated as following: The delta of the compartment diameter with high and low external pressure, divided through the diameter with low external pressure. In 10 volunteers, two examinators conducted each two measurements to assess the reliability.ResultsMean compartment compressibility ratio R10-80 was 15.9% ±3.6 (range: 7.2 - 22.2). Mean compartment compressibility ratio R0-80 was 18.2% ±5.0 (3.0 - 32.1). There was no significant correlation with lower leg circumference, height, weight, BMI, gender, hours of sport per week and type of sport (e.g. weightlifting/ cardio). For R10-80, intraobserver ICC 2.1 was 0.89 for an experienced observer and 0.79 for a non-experienced observer. Interobserver ICC 2.1 was 0.78. For R0-80, intraobserver ICC 2.1 was 0.71 for the experienced and 0.56 for the unexperienced observer. Interobserver ICC 2.1 was 0.59.DiscussionIn healthy volunteers between 18 and 50 years of age, mean compartment compressibility ratio R10-80 was 15.9% ±3.6, independent of demographic factors and sport activity. Application of 10mbar instead of 0mbar increased image quality. Subsequently, R10-80 showed lower standard deviation and both higher intraobserver and interobserver reliability than R0-80. Using R10-80, this measurement method is reliable with very high intra- and interobserver correlation.Copyright © 2021 The Authors. Published by Elsevier Ltd.. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.