• J Vet Emerg Crit Care (San Antonio) · Dec 2009

    Comparative Study

    Comparison of direct and indirect methods of intra-abdominal pressure measurement in normal horses.

    • Amelia S Munsterman and R Reid Hanson.
    • Equine Section, Department of Clinical Sciences, Auburn College of Veterinary Medicine, J.T. Vaughan Large Animal Teaching Hospital, Auburn University, Auburn, AL 36849, USA. munstas@auburn.edu
    • J Vet Emerg Crit Care (San Antonio). 2009 Dec 1; 19 (6): 545-53.

    ObjectivesTo develop a direct method for measuring intra-abdominal pressures in the standing horse, identify a reference interval for direct intra-abdominal pressures, compare these pressures to indirect intra-abdominal pressures measured from the bladder, and determine the optimal bladder infusion volume for indirect pressure measurement.DesignProspective, experimental study.SettingA university-based equine research facility.AnimalsTen healthy adult horses, 5 males and 5 females.InterventionsDirect intra-abdominal pressures were measured through an intraperitoneal cannula and zeroed at the height midway between the height of the tuber ishii and point of the shoulder. Indirect measurements of intra-abdominal pressure were performed by measuring intravesicular pressures through a transurethral catheter zeroed at the tuber ishii.Measurements And Main ResultsDirect pressure measurements obtained in the standing horse were subatmospheric (mean, -1.80 cm H(2)O; SD, 1.61 cm H(2)O; 95% CI, -2.80 to -0.80) and were shown to decrease as the horse's weight increased (Pearson's r=-0.67, P=0.04), with no effect of head position (P=0.15). Mean baseline indirect pressure measurements (mean, -8.63 cm H(2)O; SD, 4.37 cm H(2)O; 95% CI, -13.05 to -4.21) were significantly different from the pressures measured directly from the abdomen (P<0.001). Indirect pressure measurements were noted to increase with increasing volumes infused into the bladder, and were statistically different at a volume of 100 mL (P=0.004). There was low to moderate correlation between direct and indirect pressure measurements of intra-abdominal pressure over a range of fluid volumes infused into the bladder (Pearson's correlation range -0.38 to 0.58).ConclusionPressures measured directly in the standing horse were subatmospheric, and increased as the horse's weight increased. Indirect pressures measured were altered by increasing volumes infused in the bladder. There was no significant correlation between the 2 methods of intra-abdominal pressure measurement.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…