-
Observational Study
A Preliminary Retrospective Study to Assess the Short-Term Safety of Traditional Smooth or Microtextured Silicone Gel-Filled Breast Implants in Korea.
- Sanghyuk Han, Robert Kim, Tae Seob Kim, Jung Heum Park, Seung Soo Kim, Cheol Jeong, and Ji Heui Lee.
- Department of Anesthesia and Pain Medicine, Korea Cancer Center Hospital, Seoul 01812, Korea.
- Medicina (Kaunas). 2021 Dec 16; 57 (12).
AbstractBackground and objectives: We conducted this preliminary retrospective study to assess the short-term safety of silicone gel-filled breast implants (SGBIs) that are commercially available in Korean women. Materials and methods :The current retrospective, observational study was conducted in a total of 2612 patients (n = 2612) who underwent augmentation mammaplasty using breast implants at our hospitals between 1 January 2017 and 31 August 2021. Results: Overall, there were a total of 248 cases (9.49%) of postoperative complications; these include 112 cases of early seroma, 52 cases of shape deformation, 32 cases of CC, 12 cases of early hematoma, 12 cases of rupture, 12 cases of infection, 12 cases of stretch deformities with skin excess and 4 cases of rippling. Overall complication-free survival of the breast implant was estimated at 1564.32 ± 75.52 days (95% CI 1416.39-1712.32). Then, the Motiva Ergonomix™ SilkSurface showed the longest survival (1528.00 ± 157.92 days [95% CI 1218.48-1837.56]), followed by the BellaGel® SmoothFine (1458.4 ± 65.76 days [95% CI 1329.56-1587.28]), the Sebbin® Sublimity (1322.00 ± 51.20 days [95% CI 1221.64-1422.32]), the BellaGel® Smooth (1138.72 ± 161.28 days [95% CI 822.6-1454.84), the Mentor® MemoryGel™ Xtra (698.4 ± 52.64 days [95% CI 595.28-801.52]) and the Natrelle® INSPIRA™ (380.00 ± 170.88 days [95% CI 45.04-714.96]) in the decreasing order. On subgroup analysis, both the Motiva ErgonomixTM and Mentor® MemoryGel™ Xtra showed no postoperative complications. However, the BellaGel® SmoothFine, Sebbin® Sublimity and BellaGel® Smooth showed incidences of 8.87%, 4.84% and 1.61%, respectively. A subgroup analysis also showed differences in incidences of postoperative complications between microtextured and smooth breast implants (15.18% vs. 16.67%). Conclusions: In conclusion, our results indicate that diverse types of an SGBI are commercially available and their safety profile varies according to the manufacturer. Plastic surgeons should consider the safety profile of each device in selecting the optimal types of the device for Korean women who are in need of an implant-based augmentation mammaplasty. However, this warrants a single-surgeon, single-center study with long periods of follow-up.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.