• Toxicology letters · Dec 2014

    Biomonitoring occupational sevoflurane exposure at low levels by urinary sevoflurane and hexafluoroisopropanol.

    • Maria Luisa Scapellato, Mariella Carrieri, Isabella Maccà, Fabiola Salamon, Andrea Trevisan, Maurizio Manno, and Giovanni Battista Bartolucci.
    • Department of Cardiologic, Thoracic and Vascular Sciences, University of Padova, Via Giustiniani, 2, Padova 35128, Italy. Electronic address: marialuisa.scapellato@unipd.it.
    • Toxicol. Lett. 2014 Dec 1; 231 (2): 154-60.

    AbstractThis study aimed to correlate environmental sevoflurane levels with urinary concentrations of sevoflurane (Sev-U) or its metabolite hexafluoroisopropanol (HFIP) in order to assess and discuss the main issues relating to which biomarker of sevoflurane exposure is best, and possibly suggest the corresponding biological equivalent exposure limit values. Individual sevoflurane exposure was measured in 100 healthcare operators at five hospitals in north-east Italy using the passive air sampling device Radiello(®), and assaying Sev-U and HFIP concentrations in their urine collected at the end of the operating room session. All analyses were performed by gas chromatography-mass spectrometry. Environmental sevoflurane levels in the operating rooms were also monitored continuously using an infrared photoacoustic analyzer. Our results showed very low individual sevoflurane exposure levels, generally below 0.5 ppm (mean 0.116 ppm; range 0.007-0.940 ppm). Sev-U and HFIP concentrations were in the range of 0.1-17.28 μg/L and 5-550 μg/L, respectively. Both biomarkers showed a statistically significant correlation with the environmental exposure levels (Sev-U, r=0.49; HFIP, r=0.52), albeit showing fairly scattered values. Sev-U values seem to be influenced by peaks of exposure, especially at the end of the operating-room session, whereas HFIP levels by exposure on the previous day, the data being consistent with the biomarkers' very different half-lives (2.8 and 19 h, respectively). According to our results, both Sev-U and HFIP are appropriate biomarkers for assessing sevoflurane exposure at low levels, although with some differences in times/patterns of exposure. More work is needed to identify the best biomarker of sevoflurane exposure and the corresponding biological equivalent exposure limit values.Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…