    Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.

    • S G Sakka, J Kozieras, O Thuemer, and N van Hout.
    • Department of Anaesthesiology and Operative Intensive Care Medicine, Medical Center Cologne-Merheim, Cologne, Germany. sakkas@kliniken-koeln.de
    • Br J Anaesth. 2007 Sep 1;99(3):337-42.

    BackgroundRecently, continuous monitoring of cardiac output (CO) based on pulse contour analysis (Vigileo) has been introduced into practice. In this clinical study, we evaluated the accuracy of this system by comparing it with the transpulmonary thermodilution technique (TPID) in septic patients.MethodsWe studied 24 mechanically ventilated patients with septic shock (16 male, 8 female, age 26-77 yr) receiving treatment with norepinephrine who for clinical indication underwent haemodynamic monitoring by the transpulmonary thermodilution technique using a PiCCO plus system (Pulsion Medical Systems, Munich, Germany). In parallel, arterial pulse contour was applied using the femoral arterial pressure curve (FloTrac pressure sensor, Vigileo monitor, Edwards Lifesciences, Irvine, USA). After baseline measurement, mean arterial pressure was elevated by increasing norepinephrine dosage, and CO was measured again before mean arterial pressure was reduced back to baseline levels. Fluid status and ventilator settings remained unchanged throughout. At each time point, CO by transpulmonary thermodilution was calculated from three central venous bolus injections of 15 ml of saline (<8 degrees C). Linear regression and the Bland-Altman method were used for statistical analysis.ResultsOverall, CO was 6.7 (sd 1.8) (3.2-10.1) litre min(-1) for CO(TPID) and 6.2 (2.4) (3.0-17.6) litre min(-1) for CO(Vigileo((R))). Linear regression revealed: CO(Vigileo) = 1.54 + 0.72 x CO(TPID) litre min(-1), r(2) = 0.26 (P < 0.0001). Mean bias between techniques [CO(TPID)-CO(Vigileo)] was 0.5 litre min(-1) (SD 2.3 litre min(-1)). Correlation coefficients at the three time points were not significantly different from each other.ConclusionsPulse contour analysis-derived CO (Vigileo system) underestimates CO(TPID) and is not as reliable as transpulmonary thermodilution in septic patients.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.