• J Palliat Med · Mar 2010

    A Respiratory Distress Observation Scale for patients unable to self-report dyspnea.

    • Margaret L Campbell, Thomas Templin, and Julia Walch.
    • Department of Nursing Administration, Detroit Receiving Hospital, Detroit, Michigan 48201, USA. mcampbe3@dmc.org
    • J Palliat Med. 2010 Mar 1;13(3):285-90.

    BackgroundStandard measures of dyspnea rely on self-report. Cognitive impairment and nearness to death may interfere with symptom distress reporting leading to underrecognition and overtreatment or undertreatment. Previous psychometric testing of the Respiratory Distress Observation Scale (RDOS) demonstrated internal consistency and convergent validity with dyspnea self-report and discriminant validity with pain and no dyspnea. Additional testing was needed with patients unable to self-report. The aim of this study was to establish further the reliability and construct validity of a revised RDOS.MethodsAn observational design was used with 89 consecutive patients referred for inpatient palliative care consultation and at risk for dyspnea who had one or more of lung cancer, chronic obstructive pulmonary disease (COPD), heart failure, or pneumonia. Patients were observed and the RDOS scored once each day for up to three days after the initial consultation. Other measures included: dyspnea self-report, neurologic diagnoses, opioid or benzodiazepine use, peripheral oxygen saturation, end-tidal carbon dioxide level, consciousness, cognitive state, nearness to death, and patient demographics.ResultsPerfect interrater reliability across data collectors was achieved. No differences in RDOS scoring were found by patient demographics. RDOS was associated with use of oxygen (p < 0.01), oxygen saturation (p < 0.01) and nearness to death (p < 0.01). A significant decrease in RDOS was found over time corresponding with treatment (p < 0.01). The reliability of this 8-item scale using Cronbach alpha is 0.64.ConclusionsDeclining consciousness and/or cognition are expected when patients are near death. The RDOS performed well when tested with terminally ill patients who were at risk for respiratory distress, most of whom could not self-report dyspnea. The tool is sensitive to detect changes over time and measure response to treatment. The RDOS is simple to use; scoring takes less than 5 minutes. The RDOS has clinical and research utility to measure and trend respiratory distress and response to treatment.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…