• Acta Biomed · Jan 2004

    Meconium-stained amniotic fluid and fetal oxygen saturation measured by pulse oximetry during labour.

    • Alessandro Grignaffini, Emanuele Soncini, Elena Ronzoni, Emanuela Piazza, Salvatore Anfuso, and Eugenio Vadora.
    • Department of Gynaecology, Obstetrics and Neonatology, University of Parma, Parma, Italy.
    • Acta Biomed. 2004 Jan 1;75 Suppl 1:45-52.

    Background And Aim Of The WorkThe high false-positive rate of electronic fetal heart rate monitoring is the major obstacle to the correct prediction and diagnosis of intrapartum fetal distress. Fetal pulse oximetry is a safe and accurate indicator of fetal oxygenation. The aim of this study was to evaluate the clinical use of this technique for the diagnosis of fetal hypoxia and for prevention of fetal metabolic acidosis and asphyxia during labour, in the presence of meconium-stained amniotic fluid with or without abnormal fetal heart rate patterns, using a threshold value of 30% oxygen saturation.MethodsFetal blood oxygen saturation levels (SpO2) of 58 term fetuses with non-reassuring fetal status were measured during labour by fetal pulse oximetry. In 35 cases the amniotic fluid was stained with meconium at onset of labour. Mean SpO2 levels at the different stages of labour were matched against fetal heart rate patterns, the amniotic fluid status, and neonatal outcome. The 35 cases with meconium-stained amniotic fluid were compared with a control group of 28 pregnant women at term who had meconium-stained amniotic fluid during labour but were not monitored by pulse oximetry.ResultsWhen the fetal heart rate tracings were abnormal, mean SpO2values were significantly lower in the first 30 minutes of application and in the last 30 minutes of labour or before Cesarean section. Meconium-stained amniotic fluid was associated with lower SpO2values only when fetal heart monitoring showed a "non-reassuring" pattern. No cases were observed with severe neonatal acidosis, with Apgar score <7 at 5 minutes, or with other adverse neonatal events. In patients with meconium-stained amniotic fluid, neonatal outcomes were better in the group monitored by pulse oximetry versus the control group, although the differences were not statistically significant.ConclusionsContinued monitoring of fetal oxygen saturation combined with fetal heart rate monitoring may improve accuracy in the evaluation of fetal well-being. As a result, labour could be more safely managed in pregnancies with non-reassuring fetal status as measured by conventional methods, especially in the presence of meconium-stained amniotic fluid.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.