• J Magn Reson Imaging · May 2016

    Multicomponent T2 analysis of articular cartilage with synovial fluid partial volume correction.

    • Fang Liu, Rajeev Chaudhary, Walter F Block, Alexey Samsonov, and Richard Kijowski.
    • Department of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.
    • J Magn Reson Imaging. 2016 May 1; 43 (5): 1140-7.

    PurposeTo investigate the use of a three-pool model to account for the confounding effects of synovial fluid on multicomponent T2 analysis of articular cartilage using Multicomponent Driven Equilibrium Single Shot Observation of T1 and T2 (mcDESPOT).Materials And MethodsmcDESPOT was performed on the knee of eight asymptomatic volunteers and eight patients with osteoarthritis at 3.0T with multicomponent T2 maps created using the two-pool model and a three-pool model containing a nonexchanging synovial fluid water pool. The fraction of the fast-relaxing water component (FF ) and the T2 relaxation times for the fast-relaxing (T2F ) and slow-relaxing (T2S ) water components were measured in the superficial and deep layers of patellar cartilage using the two-pool and three-pool models in asymptomatic volunteers and patients with osteoarthritis and were compared using Wilcoxon signed rank tests.ResultsWithin the superficial layer of patellar cartilage, FF was 22.5% and 25.6% for asymptomatic volunteers and 21.3% and 22.8% for patients with osteoarthritis when using the two-pool and three-pool models, respectively, while T2S was 73.9 msec and 62.0 msec for asymptomatic volunteers and 72.0 msec and 63.1 msec for patients with osteoarthritis when using the two-pool and three-pool models, respectively. For both asymptomatic volunteers and patients with osteoarthritis, the two-pool model provided significantly (P < 0.05) lower FF and higher T2S than the three-pool model, likely due to the effects of synovial fluid partial volume averaging.ConclusionThe effects of partial volume averaging between superficial cartilage and synovial fluid may result in biased multicomponent T2 measurements that can be corrected using an mcDESPOT three-pool model containing a nonexchanging synovial fluid water pool.© 2015 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.