• J. Cardiothorac. Vasc. Anesth. · Aug 2022

    Reliability of Bioreactance and Pulse-Power Analysis in Measuring Cardiac Index in Patients Undergoing Cardiac Surgery With Cardiopulmonary Bypass.

    • Laura Anneli Ylikauma, Katriina Marjatta Lanning, Tiina Maria Erkinaro, Pasi Petteri Ohtonen, Merja Annika Vakkala, Janne Henrik Liisanantti, Tatu Sakari Juvonen, and Timo Ilari Kaakinen.
    • Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland. Electronic address: laura.ylikauma@gmail.com.
    • J. Cardiothorac. Vasc. Anesth. 2022 Aug 1; 36 (8 Pt A): 2446-2453.

    ObjectivesLess-invasive and continuous cardiac output monitors recently have been developed to monitor patient hemodynamics. The aim of this study was to compare the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and miniinvasive pulse-power device LiDCOrapid to bolus thermodilution technique with a pulmonary artery catheter (TDCO) when measuring cardiac index in the setting of cardiac surgery with cardiopulmonary bypass (CPB).DesignA prospective method-comparison study.SettingOulu University Hospital, Finland.ParticipantsTwenty patients undergoing cardiac surgery with CPB.InterventionsCardiac index measurements were obtained simultaneously with TDCO intraoperatively and postoperatively, resulting in 498 measurements with Starling SV and 444 with LiDCOrapid.Measurements And Main ResultsThe authors used the Bland-Altman method to investigate the agreement between the devices and four-quadrant plots with error grids to assess the trending ability. The agreement between TDCO and Starling SV was qualified with a bias of 0.43 L/min/m2 (95% confidence interval [CI], 0.37-0.50), wide limits of agreement (LOA, -1.07 to 1.94 L/min/m2), and a percentage error (PE) of 66.3%. The agreement between TDCO and LiDCOrapid was qualified, with a bias of 0.22 L/min/m2 (95% CI 0.16-0.27), wide LOA (-0.93 to 1.43), and a PE of 53.2%. With both devices, trending ability was insufficient.ConclusionThe reliability of bioreactance-based Starling SV and pulse-power analyzer LiDCOrapid was not interchangeable with TDCO, thus limiting their usefulness in cardiac surgery with CPB.Copyright © 2021 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.