• Pain physician · Jan 2022

    Multicenter Study Observational Study

    Radiation Doses for Different Approaches of Fluoroscopy-Guided Epidural Injections: An Observational Clinical Study.

    • Rekib Sacaklidir, Ekim Can Ozturk, Savas Sencan, and Osman Hakan Gunduz.
    • Division of Pain Medicine, Department of Physical Medicine and Rehabilitation, Marmara University, ?stanbul, Turkey.
    • Pain Physician. 2022 Jan 1; 25 (1): E67-E72.

    BackgroundAlthough fluoroscopy-guided interventional therapies have declined in recent years, radiation exposure remains a critical issue for both patients and medical staff. Radiation exposure varies according to the physicians' experience, procedure time, patients' body mass index (BMI), imaging techniques, and the type of procedure performed.ObjectiveThe purpose of this study is to report procedure times and calculate the radiation doses for 4 different approaches of fluoroscopy-guided epidural injections per procedure and BMI to provide radiations doses for potential use in future dose reduction strategies.Study DesignRetrospective, observational study.SettingA university hospital, pain management center.MethodsA retrospective evaluation was performed of patients who received epidural steroid injections between January 2015 and December 2020 in a university hospital interventional pain management center. This observational study was conducted with patients aged >= 18 who underwent 3,711 epidural injections including cervical interlaminar, lumbar interlaminar, lumbar transforaminal, and caudal approaches. If more than one level or bilateral injections were performed, total dose and times were divided by the number of sites injected to attain procedure time and mean dose per injection. Provided doses for each patient were also divided by patients' BMI to obtain dose per BMI.ResultsThe highest radiation dose per procedure was found in caudal epidural injection with 0.218 mGy·m2, and the lowest dose was found in cervical interlaminar epidural injection with 0.057 mGy·m2. The radiation dose per procedure was 0.123 mGy·m2 for lumbar transforaminal and 0.191 mGy·m2 for lumbar interlaminar epidural injection. The shortest procedure time was determined in transforaminal (37.3 seconds) injections, and the longest was in lumbar interlaminar (46.7 seconds) injections. Caudal epidural injection also had the highest radiation dose per BMI which was 0.00749, and cervical interlaminar epidural injection had the lowest radiation dose per BMI, which was 0.00214.LimitationsFirstly, injections were performed by first- or second-year fellows in pain medicine. Moreover, patient-related factors (previous surgery, scoliosis, etc.) affecting radiation exposure were ignored.ConclusionsRadiation dose levels and procedure times of 4 approaches of epidural injections were obtained from 3,711 procedures performed in a university hospital pain medicine clinic. BMI of patients was taken into account with the dose levels of injections given per BMI. Multicenter research with standardized techniques will assure more reliable reference levels, which will guide pain physicians to self-assess their own levels of radiation exposure.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…