-
- Vedanta Dariya, Luca Moresco, Matteo Bruschettini, and Luc P Brion.
- Department of Pediatrics, Division of Neonatal-Perinatal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Cochrane Db Syst Rev. 2022 Jan 24; 1 (1): CD013736CD013736.
BackgroundEndotracheal intubation is a commonly performed procedure in neonates, the risks of which are well-described. Some endotracheal tubes (ETT) are equipped with a cuff that can be inflated after insertion of the ETT in the airway to limit leak or aspiration. Cuffed ETTs have been shown in larger children and adults to reduce gas leak around the ETT, ETT exchange, accidental extubation, and exposure of healthcare workers to anesthetic gas during surgery. With improved understanding of neonatal airway anatomy and the widespread use of cuffed ETTs by anesthesiologists, the use of cuffed tubes is increasing in neonates.ObjectivesTo assess the benefits and harms of cuffed ETTs (inflated or non-inflated) compared to uncuffed ETTs for respiratory support in neonates.Search MethodsWe searched CENTRAL, PubMed, and CINAHL on 20 August 2021; we also searched trial registers and checked reference lists to identify additional studies.Selection CriteriaWe included randomized controlled trials (RCTs), quasi-RCTs, and cluster-randomized trials comparing cuffed (inflated and non-inflated) versus uncuffed ETTs in newborns. We sought to compare 1. inflated, cuffed versus uncuffed ETT; 2. non-inflated, cuffed versus uncuffed ETT; and 3. inflated, cuffed versus non-inflated, cuffed ETT.Data Collection And AnalysisWe used the standard methods of Cochrane Neonatal. Two review authors independently assessed studies identified by the search strategy for inclusion, extracted data, and assessed risk of bias. We used the GRADE approach to assess the certainty of evidence.Main ResultsWe identified one eligible RCT for inclusion that compared the use of cuffed (inflated if ETT leak greater than 20% with cuff pressure 20 cm H2O or less) versus uncuffed ETT. The author provided a spreadsheet with individual data. Among 76 infants in the original manuscript, 69 met the inclusion and exclusion criteria for this Cochrane Review. We found possible bias due to lack of blinding and other bias. We are very uncertain about frequency of postextubation stridor, because the confidence intervals (CI) of the risk ratio (RR) were very wide (RR 1.36, 95% CI 0.35 to 5.25; risk difference (RD) 0.03, -0.11 to 0.18; 1 study, 69 participants; very low-certainty evidence). No neonate was diagnosed with postextubation subglottic stenosis; however, endoscopy was not available to confirm the clinical diagnosis. We are very uncertain about reintubation for stridor or subglottic stenosis because the CIs of the RR were very wide (RR 0.27, 95% CI 0.01 to 6.49; RD -0.03, 95% CI -0.11 to 0.05; 1 study, 69 participants; very low-certainty evidence). No neonate had surgical intervention (e.g. endoscopic balloon dilation, cricoid split, tracheostomy) for stridor or subglottic stenosis (1 study, 69 participants). Neonates randomized to cuffed ETT may be less likely to have a reintubation for any reason (RR 0.06, 95% CI 0.01 to 0.45; RD -0.39, 95% CI -0.57 to -0.21; number needed to treat for an additional beneficial outcome 3, 95% CI 2 to 5; 1 study, 69 participants; very low-certainty evidence). We are very uncertain about accidental extubation because the CIs of the RR were wide (RR 0.82, 95% CI 0.12 to 5.46; RD -0.01, 95% CI -0.12 to 0.10; 1 study, 69 participants; very low-certainty evidence). We are very uncertain about all-cause mortality during initial hospitalization because the CIs of the RR were extremely wide (RR 2.46, 95% CI 0.10 to 58.39; RD 0.03, 95% CI -0.05 to 0.10; 1 study, 69 participants; very low-certainty evidence). There is one ongoing trial. We classified two studies as awaiting classification because outcome data were not reported separately for newborns and older infants. Evidence for comparing cuffed versus uncuffed ETTs in neonates is limited by a small number of babies in a single RCT with possible bias. There is very low certainty evidence for all outcomes of this review. CIs of the estimate for postextubation stridor were wide. No neonate had clinical evidence for subglottic stenosis; however, endoscopy results were not available to assess the anatomy. Additional RCTs are necessary to evaluate the benefits and harms of cuffed ETTs (inflated and non-inflated) in the neonatal population. These studies must include neonates and be conducted both for short-term use (in the setting of the operating room) and chronic use (in the setting of chronic lung disease) of cuffed ETTs.Copyright © 2022 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.