• Neurosurgery · Jan 1996

    Comparative Study

    Laboratory testing of three intracranial pressure microtransducers: technical report.

    • M Czosnyka, Z Czosnyka, and J D Pickard.
    • United Kingdom Shunt Evaluation Laboratory & Academic Neurosurgical Unit, Addenbrooke's Hospital, Cambridge, England.
    • Neurosurgery. 1996 Jan 1; 38 (1): 219-24.

    AbstractThree comparatively priced intracranial pressure (ICP) microtransducers are now available, each characterized by the manufacturer as having very low zero drift over long periods, an excellent frequency response, and a low measurement error. The three microtransducers, coded Transducer A (Camino OLM ICP monitor; Camino Laboratories, San Diego, CA), Transducer B (Codman Microsensor ICP Transducer; Codman & Shurtlef Inc., Randolph, MA), and Transducer C (ICP Monitoring Catheter Kit OPX-SD [4F]; InnerSpace Medical, Irvine, CA), were examined in a pressure-flow test rig designed for assessment of hydrocephalus shunts. All three microtransducers compiled with the manufacturers' specifications and gave high-quality readings under test conditions. However, some differences were noted; Transducer C had the lowest 24-hour zero drift (drifts in all transducers were < 0.8 mm Hg). The temperature drift was very low in Transducer B and C, but Transducer A had a significantly higher drift (0.27 mm Hg/degrees C). Transducer A had a static error < 0.3 mm Hg, Transducer B < 2 mm Hg, and Transducer C < 8 mm Hg. Frequency detection in Transducers A and B were very good (bandwidth, > 30 Hz), whereas Transducer C had a limited bandwidth of 20 Hz. Transducer B scored the best overall, but all three scored satisfactorily during bench testing.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…