Randomized Controlled Trial
Eye tracking for assessment of workload: a pilot study in an anaesthesia simulator environment.
- C M Schulz, E Schneider, L Fritz, J Vockeroth, A Hapfelmeier, M Wasmaier, E F Kochs, and G Schneider.
- Department of Anaesthesiology, Technische Universität München, München, Germany. c.m.schulz@lrz.tum.de
- Br J Anaesth. 2011 Jan 1;106(1):44-50.
BackgroundWorkload assessment is an important tool for improving patient safety in anaesthesia. We tested the hypothesis that heart rate, pupil size, and duration of fixation increase, whereas saccade amplitude decreases with increased workload during simulated critical incidents.MethodsFifteen trainee anaesthetists participated in this randomized cross-over trial. Each participant used a head-mounted eye-tracking device (EyeSeeCam) during induction of general anaesthesia in a full-scale simulation during three different sessions. No critical incident was simulated in the first session. In a randomized order, workload was increased by simulation of a critical incident in the second or third session. Pupil size, duration of fixations, saccadic amplitude, and heart rate of each participant and the simulator conditions were recorded continuously and synchronized. The data were analysed by paired sample t-tests and mixed-effects regression analysis.ResultsThe findings of the second and third sessions of 11 participants were analysed. Pupil diameter and heart rate increased simultaneously as the severity of the simulated critical incident increased. Allowing for individual effects, the simulator conditions explained 92.6% of the variance in pupil diameter and 93.6% of the variance in heart rate (both P<0.001). The duration of fixation decreased with increased workload. The saccadic amplitude remained unaffected by workload changes.ConclusionsPupil size and heart rate reflect workload increase within simulator sessions, but they do not permit overall workload comparisons between individuals or sessions. Contrary to our assumption, the duration of fixation decreased with increased workload. Saccade amplitude did not reflect workload fluctuations.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.