J Clin Monit Comput · Dec 2022
Memsorb™, a novel CO2 removal device part II: in vivo performance with the Zeus IE®.
- Sarah A Eerlings, Mohammed K Bashraheel, Andre M De Wolf, Arne Neyrinck, Marc Van de Velde, Geert Vandenbroucke, Rik Carette, Jeffrey Feldman, and HendrickxJan F AJFA0000-0002-1360-9662Department of Anesthesiology, OLV Hospital, Moorselbaan 164, 9300, Aalst, Belgium. jcnwahendrickx@yahoo.com.Department of Anesthesiology, UZ Leuven, Leuven, Belgium. jcnwahendrickx@yahoo.com.Department of Cardiovascul.
- Department of Anesthesiology, OLV Hospital, Moorselbaan 164, 9300, Aalst, Belgium.
- J Clin Monit Comput. 2022 Dec 1; 36 (6): 164716551647-1655.
AbstractMemsorb™ (DMF Medical, Halifax, Canada) is a novel device based upon membrane oxygenator technology designed to eliminate CO2 from exhaled gas when using a circle anesthesia circuit. Exhaled gases pass through semipermeable hollow fibers and sweep gas flowing through these fibers creates a diffusion gradient for CO2 removal. In vivo Memsorb™ performance was tested during target-controlled closed-circuit anesthesia (TCCCA) with desflurane in O2/air using a Zeus IE® anesthesia workstation (Dräger, Lübeck, Germany). Clinical care protocols for using this novel device were guided by in vitro performance results from a prior study (submitted simultaneously). After IRB approval, written informed consent was obtained from 10 ASA PS I-III patients undergoing robot-assisted radical prostatectomy. TCCCA targets were 39% inspired O2 concentration (FIO2) and 5.0% end-expired desflurane concentration (FETdes). Minute ventilation (MV) was adjusted to maintain 4.5-6.0% FETCO2. The O2/air (40% O2) sweep flow into the Memsorb™ was manually adjusted in an attempt to keep inspired CO2 concentration (FICO2) ≤ 0.8%. The following data were collected: FIO2, FETdes, FICO2, FETCO2, MV, fresh gas flow (FGF, O2 and air), sweep flow, and cumulative desflurane usage (Vdes). Vdes of the Zeus IE®-Memsorb™ combination was compared with historical Vdes observed in a previous study when soda lime (DrägerSorb 800 +) was used. Results are reported as median and inter-quartiles. A combination of manually adjusting sweep flow (26 [21,27] L/min) and MV sufficed to maintain FICO2 ≤ 0.8% and FETCO2 ≤ 6.0%, except in one patient in whom the target Zeus IE® FGF had to be increased to 0.7 L/min for 6 min. FIO2 and FETdes were maintained close to their targets. Zeus IE® FGF after 5 min was 0 [0,0] mL/min. Average Vdes after 50 min was higher with Memsorb™ (20.3 mL) compared to historical soda lime canister data (12.3 mL). During target-controlled closed-circuit anesthesia in patients undergoing robot-assisted radical prostatectomy, the Memsorb™ maintained FICO2 ≤ 0.8% and FETCO2 ≤ 6.0%, and FIO2 remained close to target. Modest amounts of desflurane were lost with the use of the Memsorb™. The need for adjustments of sweep flow, minute ventilation, and occasionally Zeus IE® FGF indicates that the Memsorb™ system should preferentially be integrated into an automated closed-loop system.© 2022. The Author(s), under exclusive licence to Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.