• Anesthesiology · May 2022

    Randomized Controlled Trial

    Quality of Labor Analgesia with Dural Puncture Epidural versus Standard Epidural Technique in Obese Parturients: A Double-blind Randomized Controlled Study.

    • Hon Sen Tan, Sydney E Reed, Jennifer E Mehdiratta, Olga I Diomede, Riley Landreth, Luke A Gatta, Daniel Weikel, and Ashraf S Habib.
    • The Department of Women's Anesthesia, KK Women's and Children's Hospital, Singapore.
    • Anesthesiology. 2022 May 1; 136 (5): 678687678-687.

    BackgroundThe dural puncture epidural technique may improve analgesia quality by confirming midline placement and increasing intrathecal translocation of epidural medications. This would be advantageous in obese parturients with increased risk of block failure. This study hypothesizes that quality of labor analgesia will be improved with dural puncture epidural compared to standard epidural technique in obese parturients.MethodsTerm parturients with body mass index greater than or equal to 35 kg · m-2, cervical dilation of 2 to 7 cm, and pain score of greater than 4 (where 0 indicates no pain and 10 indicates the worst pain imaginable) were randomized to dural puncture epidural (using 25-gauge Whitacre needle) or standard epidural techniques. Analgesia was initiated with 15 ml of 0.1% ropivacaine with 2 µg · ml-1 fentanyl, followed by programed intermittent boluses (6 ml every 45 min), with patient-controlled epidural analgesia. Parturients were blinded to group allocation. The data were collected by blinded investigators every 3 min for 30 min and then every 2 h until delivery. The primary outcome was a composite of (1) asymmetrical block, (2) epidural top-ups, (3) catheter adjustments, (4) catheter replacement, and (5) failed conversion to regional anesthesia for cesarean delivery. Secondary outcomes included time to a pain score of 1 or less, sensory levels at 30 min, motor block, maximum pain score, patient-controlled epidural analgesia use, epidural medication consumption, duration of second stage of labor, delivery mode, fetal heart tones changes, Apgar scores, maternal adverse events, and satisfaction with analgesia.ResultsOf 141 parturients randomized, 66 per group were included in the analysis. There were no statistically or clinically significant differences between the dural puncture epidural and standard epidural groups in the primary composite outcome (34 of 66, 52% vs. 32 of 66, 49%; odds ratio, 1.1 [0.5 to 2.4]; P = 0.766), its individual components, or any of the secondary outcomes.ConclusionsA lack of differences in quality of labor analgesia between the two techniques in this study does not support routine use of the dural puncture epidural technique in obese parturients.Copyright © 2022, the American Society of Anesthesiologists. All Rights Reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    This article appears in the collection: Is dural-puncture epidural superior to standard epidural labour analgesia?.

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…