• J Clin Monit Comput · Dec 2022

    Validation of the Masimo O3™ regional oximetry device in pediatric patients undergoing cardiac surgery.

    • Ji-Hyun Lee, In-Sun Song, Pyoyoon Kang, Sang-Hwan Ji, Young-Eun Jang, Eun-Hee Kim, Hee-Soo Kim, and Jin-Tae Kim.
    • Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, # 101 Daehakno, Jongnogu, Seoul, 03080, Republic of Korea.
    • J Clin Monit Comput. 2022 Dec 1; 36 (6): 170317091703-1709.

    AbstractWe assessed the accuracy of Masimo O3™ regional cerebral oxygen saturation (rSO2) readings by comparing them with reference values and evaluated the relationship between rSO2 and somatic tissue oxygen saturation (StO2) in children undergoing cardiac surgery. After anesthesia induction, pediatric sensors were applied to the forehead and foot sole, and rSO2 and StO2 values were monitored continuously. Before cardiopulmonary bypass (CPB), FIO2 was set to 0.2, 0.5, and 0.8 serially every 15 min. After CPB, FIO2 was reversed. The reference values (SavO2) were calculated by combining arterial (SaO2) and central venous oxygen saturation (SvO2) readings from the arterial and central lines, respectively (0.7 [Formula: see text] SvO2 + 0.3 [Formula: see text] SaO2). In total, 265 pairs of rSO2/StO2 and SavO2 from 49 patients were analyzed. The bias, standard deviation (SD), standard error (SE), and root mean squared error (RMSE) of rSO2 were 2.6%, 4.5%, 0.3%, and 4.3%, respectively. The limits of agreement ranged from -6.3% to 11.6%. Trend accuracy analysis yielded a relative mean error of -1.4%, with an SD of 4.3%, SE of 0.2%, and RMSE of 3.9%. According to multiple linear regression analysis, the application of CPB, FIO2, Hb level, and tip location of the central venous catheter influenced the bias (all P < 0.05). Furthermore, the correlation between rSO2 and StO2 was weak (r = 0.254). rSO2 readings by the Masimo O3™ device and pediatric sensor had good absolute and trending accuracies with respect to the calculated reference values in children undergoing cardiac surgery. rSO2 and StO2 cannot be used interchangeably.Clinical trial registration http://clinicaltrials.gov (number: NCT04208906).© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.