• Can J Anaesth · May 2022

    Meta Analysis

    Airtraq® versus GlideScope® for tracheal intubation in adults: a systematic review and meta-analysis with trial sequential analysis.

    • Hiroshi Hoshijima, Takahiro Mihara, Yohei Denawa, Toshiya Shiga, and Kentaro Mizuta.
    • Division of Dento-Oral Anesthesiology, Tohoku University Graduate School of Dentistry, 4-1 Seiryomachi, Aoba, Sendai, Miyagi, 980-8575, Japan. hhoshi6@gmail.com.
    • Can J Anaesth. 2022 May 1; 69 (5): 605-613.

    PurposeIn recent years, various types of indirect laryngoscopes have been developed. Nevertheless, no conclusions have been drawn about which type of indirect laryngoscope is most effective for tracheal intubation. We performed a systematic review and meta-analysis to determine whether the Airtraq® or the GlideScope® is more effective for tracheal intubation.MethodsWe extracted studies of adult prospective randomized trials comparing tracheal intubation between the Airtraq and GlideScope. An electronic database was used to extract the studies included in our meta-analysis. We extracted the following data from the identified studies: success rate, glottic visualization, and intubation time. Data from each trial were combined via a random-effects model for calculation of pooled relative risk (RR) or weighted mean difference (WMD) with a 95% confidence interval (CI). We also performed trial sequential analysis.ResultsWe included eight trials comprising 571 patients for review. Compared with the GlideScope, Airtraq did not improve success rate, glottic visualization, or intubation time in tracheal intubation (success rate: RR, 0.98; 95% CI, 0.91 to 1.05; P = 0.58; I2 = 65%; glottic visualization: RR, 1.07; 95% CI, 0.88 to 1.29; P = 0.69; I2 = 64%; and intubation time: WMD, 1.4 seconds ; 95% CI, -6.2 to 9.1; P = 0.72; I2 = 96%). The quality of evidence was graded as "very low." Trial sequential analysis showed that total sample size did not reach the required information size for all parameters.ConclusionIn this meta-analysis, use of the Airtraq indirect laryngoscope did not result in improved success rate, glottic visualization, or intubation time in tracheal intubation compared with the GlideScope. Trial sequential analysis suggests that further studies are necessary to confirm these findings.© 2022. Canadian Anesthesiologists' Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…