• Anesthesia and analgesia · Aug 2009

    Preinsertion paramedian ultrasound guidance for epidural anesthesia.

    • Denis Tran, Allaudin A Kamani, Victoria A Lessoway, Carly Peterson, King Wei Hor, and Robert N Rohling.
    • Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada.
    • Anesth. Analg. 2009 Aug 1;109(2):661-7.

    BackgroundUltrasound is receiving growing interest for improving the guidance of needle insertion in epidural anesthesia. Defining a paramedian ultrasound scanning technique would be helpful for correctly identifying the vertebral level. Finding surrogate measures of the depth of the epidural space may also improve the ease of scanning.MethodsWe examined 20 parturients with pre-epidural ultrasound in the paramedian plane, and the predicted depth was compared with the actual midline depth. The actual depth was also compared with subject biometrics, depth of transverse process, and thickness of lumbar fat.ResultsThe scanning technique allowed the depth of the epidural space to be measured in all subjects. The depth measured in ultrasound was strongly correlated to the actual depth (R(2) = 0.8 and 95% limits of agreement of -14.8 to 5.2 mm), unlike patient biometrics (R(2) < 0.25), the depth of the neighboring transverse processes (R(2) = 0.35 and 95% limits of agreement of -13.8 to 19.1 mm), or the thickness of overlying fat (R(2) = 0.66). The duration of the ultrasound scan was 10 min at the beginning of the trial and 3 min for the last subjects.ConclusionsParamedian ultrasound can be used to estimate the midline depth to the epidural space. The surrogate measures are not sufficiently correlated with the depth to the epidural space to recommend them as a replacement for the actual depth to the epidural space measurement.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.