J. Cardiothorac. Vasc. Anesth. · Aug 2022
Observational StudyUtility of Transfontanelle Ultrasound in Predicting the Fluid Responsiveness in Children After Repair of Congenital Heart Diseases: A Prospective Observational Study.
- Avneet Singh, Bhupesh Kumar, Goverdhan Dutt Puri, ThingnamShyam Kumar SinghSKSDepartment of Cardiothoracic and Vascular Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India., Sunder Lal Negi, and Subrashsih Guha Niyogi.
- Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
- J. Cardiothorac. Vasc. Anesth. 2022 Aug 1; 36 (8 Pt A): 2358-2364.
ObjectivesPostoperative fluid management in children undergoing cardiac surgery requires a balanced optimization. The blood flow velocity variation in the internal carotid artery (ΔICA) measured through transfontanelle ultrasound has been shown to predict fluid responsiveness during cardiac surgery. It may provide an excellent window to study fluid responsiveness in infants during the postoperative period when the intensivist is faced with the challenges of poor echocardiographic window. The authors aimed to observe the correlation between ΔICA measured on transfontanelle ultrasound with the respiratory variability of peak aortic blood flow velocity (ΔVpeak) on transthoracic echocardiography as a marker of fluid responsiveness in infants on mechanical ventilation during the postoperative period after cardiac surgery.DesignA prospective observational study.SettingThe postcardiac surgery intensive care unit (ICU) of a tertiary care hospital.ParticipantsThirty infants undergoing congenital cardiac surgery.InterventionsA fluid bolus of 10 mL/kg administered over 10 minutes at 1 and 6 hours after ICU admission. Patients were categorized into fluid responders and nonresponders based on >15% increase in the indexed stroke volume.Measurements And Main ResultsA total of 50 fluid boluses were administered in 30 patients. Among these, 22 (73.33%) were responders and 8 (26.67%) were nonresponders. There was moderate correlation between ΔICA and peak aortic blood flow velocity variation (ΔVpeak) (r = 0.59, p ≤ 0.001). The ΔVpeak >14.74% had 68% sensitivity and 75% specificity to predict fluid responsiveness (area under the receiver operating characteristic [AUROC], 0.749; p = 0.001; positive likelihood ratio, 2.71; negative likelihood ratio, 0.43). The ΔICA >9.85% could predict fluid responsiveness in infants (AUROC, 0.728; p = 0.003; 75% sensitivity; 60% specificity; positive likelihood ratio, 1.85; negative likelihood ratio, 0.42). Among children younger than 6 months, ΔICA >9.85% was a better predictor of fluid responsiveness (AUROC, 0.889; p = 0.009) than ΔVpeak >15% (AUROC, 0.778; p = 0.061).ConclusionThe ICA variability >9.85% measured via transfontanelle ultrasound is a good predictor of fluid responsiveness in infants, especially those younger than 6 months on mechanical ventilation after cardiac surgery.Copyright © 2022 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.