• J. Thorac. Cardiovasc. Surg. · May 2022

    One-year results with a low-profile endograft in subjects with thoracic aortic aneurysm and ulcer pathologies.

    • Wilson Y Szeto, Prashanth Vallabhajosyula, Hitoshi Matsuda, Sina L Moainie, Mel J Sharafuddin, Joel Corvera, Christopher J Smolock, Shinji Miyamoto, Thomas Naslund, Venkatesh Ramaiah, and RelayPro-A Investigators.
    • University of Pennsylvania School of Medicine, Philadelphia, Pa. Electronic address: wilson.szeto@pennmedicine.upenn.edu.
    • J. Thorac. Cardiovasc. Surg. 2022 May 1; 163 (5): 1739-1750.e4.

    ObjectiveThe study objective was to evaluate the safety and effectiveness of the second-generation, low-profile RelayPro (Terumo Aortic) thoracic endograft for the treatment of descending thoracic aortic aneurysm or penetrating atherosclerotic ulcer.MethodA prospective, international, nonblinded, nonrandomized, pivotal trial analyzed a primary safety end point of major adverse events at 30 days (death, myocardial infarction, stroke, renal/respiratory failure, paralysis, bowel ischemia, procedural blood loss) and a primary effectiveness end point of treatment success at 1 year (technical success, patency, absence of aneurysm rupture, type I/III endoleaks, stent fractures, reinterventions, aneurysm expansion, and migration) compared with performance goals from the previous generation Relay pivotal study. The study was conducted in 36 centers in the United States and Japan and enrolled participants between 2017 and 2019.ResultsThe study population of 110 patients had a median (interquartile range) age of 76 (70-81) years, 69 (62.7%) were male, and 43 (39.1%) were Asian. Patients were treated for 76 fusiform aneurysms (69%), 24 saccular aneurysms (22%), and 10 penetrating atherosclerotic ulcers (9%). Most patients (82.7%) were treated with a non-bare stent configuration. Technical success was 100%. The median (interquartile range) procedure time was 91 (64-131) minutes, and the deployment time was 16 (10-25) minutes. A total of 50 patients (73.5%) in the US cohort had percutaneous access, whereas centers in Japan used only surgical cutdown. The 30-day composite major adverse events rate was 6.4% (95% upper confidence interval, 11.6%; P = .0002): 2 strokes, 2 procedural blood losses greater than 1000 mL requiring transfusion, 2 paralysis events, and 1 renal failure. Primary effectiveness was 89.2% (lower 95% confidence interval, 81.8%; P = .0185). Nine subjects experienced 11 events (1 aneurysm expansion, 6 secondary interventions, and 4 type I endoleaks). There was no loss of stent-graft patency, no rupture, no fractures, and no migration.ConclusionsThe low-profile RelayPro thoracic endograft met the study primary end points and demonstrated satisfactory 30-day safety and 1-year effectiveness for the treatment of patients with aneurysms of the descending thoracic aorta or penetrating atherosclerotic ulcers. Follow-up is ongoing to evaluate longer-term outcomes and durability.Copyright © 2022. Published by Elsevier Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.