Anesthesia and analgesia · Jul 2022
Randomized Controlled TrialContinuous Titration of Inspired Oxygen Using Oxygen Reserve Index to Decrease Oxygen Exposure During One-Lung Ventilation: A Randomized Controlled Trial.
- Mikyung Yang, Jie Ae Kim, Hyun Joo Ahn, Young Soo Choi, MiHye Park, Heejoon Jeong, Keoungah Kim, and Nam Young Lee.
- From the Departments of Anesthesiology and Pain Medicine.
- Anesth. Analg. 2022 Jul 1; 135 (1): 919991-99.
BackgroundA high fraction of inspired oxygen (Fio2) is administered during one-lung ventilation (OLV). However, a high Fio2 is not physiologic and may lead to various complications. We hypothesized that continuous titration of Fio2 using the oxygen reserve index (ORI) reduces oxygen exposure compared to conventional management during OLV.MethodsIn this randomized, double-blinded trial, patients undergoing thoracic surgery were assigned to an ORI (n = 64) or a control group (n = 60). In the ORI group, ORI was continuously displayed using multiwavelength pulse co-oximetry (Masimo) between 0 and 1 (0, no reserve; 1, maximum reserve), and Fio2 was titrated for a target ORI of 0.21 at 5-minute intervals during OLV. In the control group, Fio2 was adjusted using arterial blood gas analysis measured at 15 minutes after OLV initiation. The primary end point was the time-weighted average Fio2 during OLV.ResultsOverall, time-weighted average Fio2 did not differ between the groups (control versus ORI: median [interquartile range], 0.87 [0.73-1.00] vs 0.82 [0.68-0.93]; P = .09). However, in a subgroup analysis, the ORI group reduced time-weighted average Fio2 after pulmonary vascular ligation compared to the control group (control versus ORI: median [interquartile range], 0.75 [0.70-1.00] vs 0.72 [0.59-0.89]; P = .0261). The incidence of intraoperative hypoxia (arterial oxygen saturation [Spo2] <94%; control versus ORI: 32% [19/60; 95% confidence interval (CI), 20-45] vs 19% [12/64; 95% CI, 10-31]; P = .09), and postoperative complications within the first 7 days did not differ between the groups.ConclusionsORI-guided continuous Fio2 titration does not reduce overall oxygen exposure during OLV.Copyright © 2022 International Anesthesia Research Society.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.