Anesthesia and analgesia · May 2009
Randomized Controlled TrialA combination of electroencephalogram and auditory evoked potentials separates different levels of anesthesia in volunteers.
- Bettina Horn, Stefanie Pilge, Eberhard F Kochs, Gudrun Stockmanns, Andreas Hock, and Gerhard Schneider.
- Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany.
- Anesth. Analg. 2009 May 1;108(5):1512-21.
BackgroundIt has been shown that the combination of electroencephalogram (EEG) and auditory evoked potentials (AEP) allows a good separation of consciousness from unconsciousness. In the present study, we sought a combined EEG/AEP indicator that allows both separation of consciousness from unconsciousness and discrimination among different levels of sedation and hypnosis over a wider range of anesthesia.MethodsFifteen unpremedicated volunteers received mono-anesthesia with sevoflurane or propofol in a randomized crossover design in two consecutive sessions. Loss of consciousness (LOC) and EEG burst suppression (BSP) defined end-points from the upper and lower range of general anesthesia. In addition to those two extremes, the difference between anesthetic concentration at BSP and LOC was divided into three equal intervals, resulting in two intermediate levels which divided the concentration from LOC (minimum) to BSP (maximum) into three equal steps. This data set was used to test whether a previously described combined EEG/AEP indicator "detector of consciousness" can also discriminate among degrees of anesthetic effects from the awake state to BSP. Furthermore, a new improved combined EEG/AEP indicator was developed on the basis of the data from the current study, and subsequently this new indicator was tested for its ability to separate consciousness from unconsciousness with the patient data set.ResultsThe former "detector of consciousness" showed a prediction probability (P(K)) of 0.77 to separate different levels of anesthesia from the current study, whereas for the new combined EEG/AEP indicator, P(K) was 0.94. The new indicator was further applied to the previous study and achieved a P(K) of 0.89.ConclusionsThese results show that with the new indicator presented here, a combination of EEG and AEP parameters can be used to differentiate degrees of anesthetic effects over a wide range of hypnosis, from the conscious state to deep anesthesia (i.e., BSP).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.