• Paediatric anaesthesia · Jun 2022

    Randomized Controlled Trial

    The effect of end-tidal carbon dioxide level on the optic nerve sheath diameter measured by transorbital ultrasonography in anesthetized pediatric patients: a randomized trial.

    • Young-Eun Jang, SeungPyo Nam, Sang-Hwan Ji, Eun-Hee Kim, Ji-Hyun Lee, Jae Ho Jung, Hee-Soo Kim, and Jin-Tae Kim.
    • Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, South Korea.
    • Paediatr Anaesth. 2022 Jun 1; 32 (6): 754-763.

    BackgroundIntraoperative hypercapnia and hypocapnia are common during pediatric anesthesia, and the cerebral blood flow and intracranial pressure may be affected by the partial pressure of arterial carbon dioxide. Transorbital ultrasound measurement of the optic nerve sheath diameter is a simple and non-invasive method for intracranial pressure assessment. The objective of this study was to evaluate the effect of end-tidal carbon dioxide (ET CO2 ) on optic nerve sheath diameter in a healthy anesthetized pediatric population.MethodsPediatric patients scheduled for elective surgery under general anesthesia and mechanical ventilation in the supine position were enrolled and divided into four subgroups; age <2 years, 2-6 years, 6-12 years, and 12-18 years. Mechanical ventilation was adjusted to achieve target ET CO2 levels in a randomized sequence (40-35-45-40 mmHg or 40-45-35-40 mmHg). Three minutes after reaching each target ET CO2 level, transorbital ultrasound images of optic nerve sheath diameter were obtained and analyzed. The primary outcome was the optic nerve sheath diameter at each ET CO2 level.ResultsSixty-four pediatric patients were enrolled and analyzed. At ET CO2  = 40 mmHg, the optic nerve sheath diameter was 5.6 ± 0.6 mm, 6.4 ± 0.5 mm, 6.8 ± 0.6 mm, and 7.1 ± 0.5 mm in children aged <2 years, 2-6 years, 6-12 years, and 12-18 years, respectively. The overall percent decreases in the optic nerve sheath diameter was -5.6 ± -4.3% (95% CI; -6.7 to -4.5%) at ET CO2  = 35 mmHg while the overall percent increases of optic nerve sheath diameter (ONSD) was 4.9 ± 5.1% (95% CI; 3.6 to 6.1%) at ET CO2  = 45 mmHg compared with those at ET CO2  = 40 mmHg. Spearman rank correlation analysis indicated that there were weak to moderate correlation between ET CO2 and the optic nerve sheath diameter (correlation coefficient [p-value] = .355 [.004], .318 [.014], .373 [<.001], and .420 [<.001] in children aged <2 years, 2-6 years, 6-12 years, and 12-18 years, respectively).ConclusionsThe optic nerve sheath diameter measured by transorbital ultrasound showed rapid reactivity from ET CO2 35 to 45 mmHg in healthy pediatric patients under inhalation general anesthesia.© 2022 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…