• J Eval Clin Pract · Jun 2009

    Monitoring surgical performance: an application to total hip replacement.

    • David J Biau, Alexandre Milet, Fabrice Thévenin, Philippe Anract, and Raphaël Porcher.
    • Département de chirurgie orthopédique, Hôpital Cochin, AP-HP, Université Paris 5, France. djmbiau@yahoo.fr
    • J Eval Clin Pract. 2009 Jun 1; 15 (3): 420-4.

    Rationale, Aims And ObjectivesInadequate surgical implantation of a hip replacement may result in decreased patient satisfaction and reduced implant survival. The objective was to monitor surgical performance in hip replacement.MethodThe study took place at a teaching centre. All primary total hip replacements were prospectively included in the series. For each hip replacement, intraoperative technical errors, cup and stem fixation and position, and postoperative complications were recorded. If all items rated were correct, the procedure was considered as correct. The Cumulative Sums (CUSUM) test was used to monitor the performance of the centre. A 90% proportion of successful procedures was considered as adequate performance and a 75% proportion of successful procedures was deemed as inadequate performance. Meetings were conducted to discuss the results of monitoring.ResultsEighty-three total hip replacements were monitored. Overall, 28 procedures (34%) were considered inadequate. The most potent reasons for inadequate performance were cup positioning and stem fixation. The CUSUM test signalled after the second procedure that performance was inadequate. After the first meeting, despite an improvement was seen, the CUSUM test raised an alarm indicating inadequate performance. The study was stopped after the second meeting because of funding reasons before it could be demonstrated that performance had reached the desired level.ConclusionThis study has demonstrated that implementing a dedicated system to monitor surgical performance in a teaching hospital improves the quality of implantation of total hip replacements. Nonetheless, the target of ninety percent of adequate primary total hip replacement could not be reached and efforts should be continued.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…