• Niger J Clin Pract · Jun 2018

    Is Low-level laser therapy and gaseous ozone application effective on osseointegration of immediately loaded implants?

    • I R Karaca, G Ergun, and D N Ozturk.
    • Department of Oral and Maxillofacial Surgery, Gazi University, Faculty of Dentistry, Ankara, Turkey.
    • Niger J Clin Pract. 2018 Jun 1; 21 (6): 703-710.

    PurposeThe purpose of this study was to investigate the effects of biostimulation lasers and ozone therapy on osseointegration of immediately loaded implants.Materials And MethodsA total number of 100 implants (DTI Implant Systems) were applied to 25 patients evenly. Temporary crowns were applied to each patient on the same session as the surgery. Implants were divided into four treatment groups (Group 1: low-level laser therapy (LLLT) group, Group 2: ozone therapy group, Group 3: different protocol of ozone therapy group, and Group 4: control group) each with 25 implants. The irradiations were performed with a gallium-aluminum-arsenide diode low-level laser (Laser BTL-4000) to Group 1. Ozone therapy was performed using an ozone generator (OzoneDTA) with an intraoral probe to Group 2 and Group 3.ResultsIn this study, the overall implant survival rate was 92% after a 6-month observation period. The implant stability quotient values were found significantly higher in Group 1 (LLLT group) and Group 3 (different protocol of ozone therapy group) than the other groups (P < 0.05). There was no significant difference in Group 2 (ozone therapy group) and the control group (P > 0.05).ConclusionsOur results suggest that both LLLT and ozone therapy with prolonged application time are promising methods to enhance bone healing around immediately loaded implants and increase implant stability; however, there is a need for more studies on this subject for these methods to become routine applications.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…