• Injury · Jun 2022

    Randomized Controlled Trial

    Application of optimized three-dimensional digital surgical guide plates for complex midfacial fractures.

    • Guikun Xu, Xiaojie Zhang, Peihan Wang, and Jie Long.
    • The State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China; Department of Oral and Maxillofacial Surgery, West China College of Stomatology, Sichuan University, Chengdu 610041, China; National Engineering Laboratory for Oral Regenerative Medicine, Chengdu 610041, China.
    • Injury. 2022 Jun 1; 53 (6): 2005-2015.

    IntroductionThe treatment of midfacial fractures is always difficult. The purpose of this study was to verify whether optimized three-dimensional (3D) digital surgical guide plates combined with preformed titanium plates improved the treatment effect in complex midfacial fractures.Patients And MethodsTwenty-six patients with complex midfacial fractures were recruited and randomized into three groups: ten for Group A, eight for Group B, and eight for Group C. Group A was treated with a combination of preformed titanium plates and optimized 3D digital surgical guide plates. Group B was treated with preformed titanium plates only. Group C was treated conventionally. Clinical effects, patient-reported outcome measures (PROMs), midfacial contour, facial symmetry, surgical accuracy, △orbital volume (the absolute value of the bilateral orbital volume difference), and maximum deviation were evaluated in each of the three groups.ResultsGroup A had the best postoperative clinical effects and patient-reported outcomes. Significant improvements in midfacial contour (L1[0.72±0.29 mm, P = 0.001], L2[1.04±0.46 mm, P < 0.001]), facial symmetry (S1[0.71±0.30 mm, P < 0.001], S2[0.96±0.58 mm, P < 0.001], S3[0.86±0.40 mm, P < 0.001], S5[0.81±0.16 mm, P = 0.003], S8[0.95±0.30 mm, P < 0.001], S9[1.03±0.38 mm, P < 0.001], S11[0.64±0.46 mm, P < 0.001]) and surgical accuracy (M1[R, 0.82±0.31 mm, P < 0.001], M2[R, 0.87±0.44 mm, P < 0.001], M3[L, 0.88±0.22 mm, P = 0.004], M3[R, 1.06±0.31 mm, P = 0.003], M4[L, 0.96±0.45 mm, P = 0.008], M4[R, 1.11±0.57 mm, P = 0.003], M5[R, 0.76±0.26 mm, P < 0.001], M6[L, 1.00±0.46 mm, P = 0.003], M6[R, 1.00±0.58 mm, P = 0.001], M7[0.87±0.53 mm, P = 0.001], M8[R, 0.91±0.53 mm, P < 0.001], M9[R, 0.81±0.32 mm, P = 0.010], M10[R, 1.19±0.42 mm, P = 0.009], M11[L, 0.85±0.51 mm, P = 0.021], M11[R, 0.96±0.49 mm, P = 0.003]) were found in Group A compared with the other two groups. The results of △orbital volume and maximum deviation analysis showed an ideal surgical treatment effect in Group A.ConclusionOptimized 3D digital guide plates can accurately locate preformed titanium plates and effectively improve the treatment effect in complex midfacial fractures.Copyright © 2022. Published by Elsevier Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…