-
Randomized Controlled Trial Multicenter Study
Volume replacement therapy during major orthopedic surgery using Voluven (hydroxyethyl starch 130/0.4) or hetastarch.
- Sweeta D Gandhi, Richard B Weiskopf, Cornelius Jungheinrich, Robert Koorn, Diane Miller, Robert E Shangraw, Donald S Prough, Daniela Baus, Frank Bepperling, and David C Warltier.
- Department of Anesthesiology, Clement J. Zablocki Veterans Affairs Medical Center and the Medical College of Wisconsin, Milwaukee, Wisconsin 53226, USA. sdgandhi@mcw.edu
- Anesthesiology. 2007 Jun 1;106(6):1120-7.
BackgroundThe purpose of this study was to test the equivalence of efficacy and compare the safety of the 6% hydroxyethyl starches (HES) Voluven (HES 130/0.4; Fresenius Kabi, Bad Homburg, Germany) and hetastarch (HES 670/0.75 in saline) for intravascular volume replacement therapy during major orthopedic surgery.MethodsIn a prospective, controlled, randomized, double-blind, multicenter trial of patients undergoing major orthopedic surgery, 49 patients were treated with HES 130/0.4 and 51 patients were treated with hetastarch. Infusion of colloids was guided by central venous and arterial blood pressures. The primary efficacy endpoint was the volume of colloid solution infused; the primary safety endpoints were calculated total erythrocyte loss, the nadir factor VIII activity, and the nadir von Willebrand factor concentration within 2 h of completion of surgery.ResultsThe total volume of colloid solution required for intraoperative volume replacement did not differ between HES 130/0.4 and hetastarch (1,613+/-778 [SD] ml for HES 130/0.4 and 1,584+/-958 ml for hetastarch). The nadir factor VIII activity within 2 h of the end of surgery was lower for hetastarch than for HES 130/0.4 (P=0.0499); for those who received greater than 1,000 ml colloid, the nadir factor VIII activity and von Willebrand factor concentration within 2 h of end of surgery were lower for hetastarch than for HES 130/0.4 (P=0.0487 and P=0.008, respectively).ConclusionVoluven (HES 130/0.4) and hetastarch are equally efficacious plasma volume substitutes; however, HES 130/0.4 has a lesser effect on coagulation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.