• Journal of neurosurgery · Mar 2012

    Case Reports

    Dural sinus stent placement for idiopathic intracranial hypertension.

    • David A Kumpe, Jeffrey L Bennett, Joshua Seinfeld, Victoria S Pelak, Ashish Chawla, and Mary Tierney.
    • Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado 80045, USA. david.kumpe@ucdenver.edu
    • J. Neurosurg. 2012 Mar 1; 116 (3): 538-48.

    ObjectThe use of unilateral dural sinus stent placement in patients with idiopathic intracranial hypertension (IIH) has been described by multiple investigators. To date there is a paucity of information on the angiographic and hemodynamic outcome of these procedures. The object of this study was to define the clinical, angiographic, and hemodynamic outcome of placement of unilateral dural sinus stents to treat intracranial venous hypertension in a subgroup of patients meeting the diagnostic criteria for IIH.MethodsEighteen consecutive patients with a clinical diagnosis of IIH were treated with unilateral stent placement in the transverse-sigmoid junction region. All patients had papilledema. All 12 female patients had headaches; 1 of 6 males had headaches previously that disappeared after weight loss. Seventeen patients had elevated opening pressures at lumbar puncture. Twelve patients had opening pressures of 33-55 cm H(2)O. All patients underwent diagnostic cerebral arteriography that showed venous outflow compromise by filling defects in the transverse-sigmoid junction region. All patients underwent intracranial selective venous pressure measurements across the filling defects. Follow-up arteriography was performed in 16 patients and follow-up venography/venous pressure measurements were performed in 15 patients.ResultsInitial pressure gradients across the filling defects ranged from 10.5 to 39 mm Hg. Nineteen stent procedures were performed in 18 patients. One patient underwent repeat stent placement for hemodynamic failure. Pressure gradients were reduced in every instance and ranged from 0 to 7 mm Hg after stenting. Fifteen of 16 patients in whom ophthalmological follow-up was performed experienced disappearance of papilledema. Follow-up arteriography in 16 patients at 5-99 months (mean 25.3 months, median 18.5 months) showed patency of all stents without in-stent restenosis. Two patients had filling defects immediately above the stent. Four other patients developed transverse sinus narrowing above the stent without filling defects. One of these patients underwent repeat stent placement because of hemodynamic deterioration. Two of the other 3 patients had hemodynamic deterioration with recurrent pressure gradients of 10.5 and 18 mm Hg.ConclusionsAll stents remained patent without restenosis. Stent placement is durable and successfully eliminates papilledema in appropriately selected patients. Continuing hemodynamic success in this series was 80%, and was 87% with repeat stent placement in 1 patient.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…