• Acad Emerg Med · Nov 2008

    Decreasing lab turnaround time improves emergency department throughput and decreases emergency medical services diversion: a simulation model.

    • Alan B Storrow, Chuan Zhou, Gary Gaddis, Jin H Han, Karen Miller, David Klubert, Andy Laidig, and Dominik Aronsky.
    • Department of Emergency Medicine, Vanderbilt University, Nashville, TN, USA. alan.storrow@vanderbilt.edu
    • Acad Emerg Med. 2008 Nov 1;15(11):1130-5.

    BackgroundThe effect of decreasing lab turnaround times on emergency department (ED) efficiency can be estimated through system-level simulation models and help identify important outcome measures to study prospectively. Furthermore, such models may suggest the advantage of bedside or point-of-care testing and how they might affect efficiency measures.ObjectivesThe authors used a sophisticated simulation model in place at an adult urban ED with an annual census of 55,000 patient visits. The effect of decreasing turnaround times on emergency medical services (EMS) diversion, ED patient throughput, and total ED length of stay (LOS) was determined.MethodsData were generated by using system dynamics analytic modeling and simulation approach on 90 separate days from December 2, 2007, through February 29, 2008. The model was a continuous simulation of ED flow, driven by real-time actual patient data, and had intrinsic error checking to assume reasonable goodness-of-fit. A return of complete laboratory results incrementally at 120, 100, 80, 60, 40, 20, and 10 minutes was compared. Diversion calculation assumed EMS closure when more than 10 patients were in the waiting room and 100% ED bed occupancy had been reached for longer than 30 minutes, as per local practice. LOS was generated from data insertion into the patient flow stream and calculation of time to specific predefined gates. The average accuracy of four separate measurement channels (waiting room volume, ED census, inpatient admit stream, and ED discharge stream), all across 24 hours, was measured by comparing the area under the simulated curve against the area under the measured curve. Each channel's accuracy was summed and averaged for an overall accuracy rating.ResultsAs lab turnaround time decreased from 120 to 10 minutes, the total number of diversion days (maximum 57 at 120 minutes, minimum 29 at 10 minutes), average diversion hours per day (10.8 hours vs. 6.0 hours), percentage of days with diversion (63% vs. 32%), and average ED LOS (2.77 hours vs. 2.17 hours) incrementally decreased, while average daily throughput (104 patients vs. 120 patients) increased. All runs were at least 85% accurate.ConclusionsThis simulation model suggests compelling improvement in ED efficiency with decreasing lab turnaround time. Outcomes such as time on EMS diversion, ED LOS, and ED throughput represent important but understudied areas that should be evaluated prospectively. EDs should consider processes that will improve turnaround time, such as point-of-care testing, to obtain these goals.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.