• J Clin Monit Comput · Jan 2000

    Hierarchical rule-based monitoring and fuzzy logic control for neuromuscular block.

    • J S Shieh, S Z Fan, L W Chang, and C C Liu.
    • Department of Mechanical Engineering, Yuan Ze University, Chung-Li, Taoyuan, Taiwan. jsshieh@saturn.yzu.edu.tw
    • J Clin Monit Comput. 2000 Jan 1; 16 (8): 583-92.

    ObjectiveThe important task for anaesthetists is to provide an adequate degree of neuromuscular block during surgical operations, so that it should not be difficult to antagonize at the end of surgery. Therefore, this study examined the application of a simple technique (i.e., fuzzy logic) to an almost ideal muscle relaxant (i.e., rocuronium) at general anaesthesia in order to control the system more easily, efficiently, intelligently and safely during an operation.MethodsThe characteristics of neuromuscular blockade induced by rocuronium were studied in 10 ASA I or II adult patients anaesthetized with inhalational (i.e., isoflurane) anaesthesia. A Datex Relaxograph was used to monitor neuromuscular block. And, ulnar nerve was stimulated supramaximally with repeated train-of-four via surface electrodes at the wrist. Initially a notebook personal computer was linked to a Datex Relaxograph to monitor electromyogram (EMG) signals which had been pruned by a three-level hierarchical structure of filters in order to design a controller for administering muscle relaxants. Furthermore, a four-level hierarchical fuzzy logic controller using the fuzzy logic and rule of thumb concept has been incorporated into the system. The Student's test was used to compare the variance between the groups. p < 0.05 was considered significant.ResultsThe system achieved stable control of muscle relaxation with a mean T1% error of -0.19 (SD 0.66) % accommodating a range in mean infusion rate (MIR) of 0.21-0.49 mg x kg(-1) x h(-1). When these results were compared with our previous ones using the same hierarchical structure applied to mivacurium, less variation in the T1% error (p < 0.05) but the same variation in infusion rate were observed. The controller activity of these two drugs showed no significant difference (p > 0.5). However, the consistent medium coefficient variance (CV) of the MIR of both rocuronium (i.e., 36.13 (SD 9.35) %) and mivacurium (i.e., 34.03 (SD 10.76) %) indicated a good controller activity.ConclusionsThe results showed that a hierarchical rule-based monitoring and fuzzy logic control architecture can provide stable control of neuromuscular block despite the considerable individual variation in neuromuscular block required among patients. Also, there was less variation in T1% error compared with that of previous study on mivacurium. Meanwhile, the consistent medium CV of the MIR of both rocuronium and mivacurium indicated a good controller activity which is able to withstand noise, diathermy effect, artifacts and surgical disturbances.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.