-
J Intensive Care Med · Feb 2015
ReviewDo clinical parameters predict first planned extubation outcome in the pediatric intensive care unit?
- James L Laham, Patrick J Breheny, and Amanda Rush.
- St. Mary's Hospital, PICU/Pediatrics, Richmond, VA, USA jlaham@sbcglobal.net.
- J Intensive Care Med. 2015 Feb 1;30(2):89-96.
ContextThere is absence of evidence-based guidelines to determine extubation readiness in the pediatric intensive care unit (PICU).ObjectiveEvaluate our practice of determining extubation readiness based on physician judgment of preextubation ventilator settings, blood gas analysis, and other factors potentially affecting extubation outcome.DesignProspective cohort study from August 2010 to April 2012.SettingAcademic, multidisciplinary PICU.PatientsA total of 319 PICU patients undergoing first planned extubation attempt.InterventionsNone.MeasurementsDetermine the extubation success rate and evaluate factors potentially affecting extubation outcome. The PICU length of stay (LOS) and cost were also recorded. Subgroup analysis was performed based on days of mechanical ventilation (MV).ResultsA total of 319 consecutive patients underwent first planned extubation attempt with a 91% success rate. Factors associated with extubation failure were the length of MV (P < .0001, odds ratio [OR] 2.20); age (P = .02, OR 0.54); preextubation steroids (P = .04, OR 2.40); and postextubation stridor (P < .01, OR 3.40). Ventilator settings and blood gas results had no association with extubation outcome with 1 exception, ventilator rates ≤ 8 were associated with extubation failure in patients with ≤1 day of MV. Extubation failure was associated with prolonged PICU LOS and excess cost, with failures staying 14 days longer (P < .0001) and costing 3.2 time more (P < .0001) than successes.ConclusionsPhysician judgment to determine extubation readiness led to a first planned extubation success rate of 91%. Age and the length of MV were primary risk factors for failed extubation. In patients with ≤1 day of MV, our findings suggest that confidence in extubation readiness following weaning to low ventilator rates may not be justified. Furthermore, reliance on preextubation ventilator settings and blood gas results to determine extubation readiness may lead to unnecessary prolongation of MV, thereby increasing the PICU LOS and excess cost. These findings are hypothesis generating and require further study for confirmation.© The Author(s) 2013.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.