-
- S Talluri, S K Vaddamanu, V Apparaju, R Vyas, S Ahuja, and M A Kanji.
- Department of Periodontology and Oral Implantology, Rambabu Dental Hospital, Ongole, India.
- Niger J Clin Pract. 2019 Jul 1; 22 (7): 982-987.
BackgroundPrimary and long-term implant stabilities are crucial in predicting the success of dental implants. We aimed to evaluate corticocancellous ratio (CCR) around virtual implant using cone beam computed tomography (CT) and assess its relationship with immediate and long-term stability of the implants placed.Materials And MethodsA total of 135 image records of posterior mandibular implant sites planned for dental implant were included in our study. CCR was calculated using CT images and implants were placed after stent preparation. Implant stability was calculated immediately, 4 months later, and 2 years later.ResultsPearson's correlation test showed a significant correlation (P and lt; 0.001) between CCR and implant stability. ANOVA and post-hoc Tukey tests showed a significant difference in implant stability between groups with different CCRs at all follow-up timepoints. No significant difference was found between mean implant stability quotient values for low CCR at 2-year follow-up and high CCR immediately after implant placement.ConclusionsImplant stability is improved with greater CCR. Cortical bone seems to be crucial factor for immediate and long-term stability of a dental implant. Virtual planning using CT can assess implant stability. Further histological studies are required to confirm the relation between CCR and implant stability. The escalating demand of the implant treatment in the dental practice necessitates measuring the several predictors of procedure success. This study introduces a novel predictor (CCR) around virtual implant for detecting the immediate and long-term stability of a dental implant.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.