• Reg Anesth Pain Med · Jan 2003

    Delivery rate accuracy of portable, bolus-capable infusion pumps used for patient-controlled continuous regional analgesia.

    • Brian M Ilfeld, Timothy E Morey, and F Kayser Enneking.
    • Department of Anesthesiology, University of Florida College of Medicine, Gainesville, Florida, USA.
    • Reg Anesth Pain Med. 2003 Jan 1;28(1):17-23.

    Background And ObjectivesPortable patient-controlled pumps used for perineural local anesthetic infusion appear to be gaining acceptance and are used for an increasing number of medically unsupervised ambulatory patients. The infusion rate accuracy and reliability of these pumps, which allow patient-controlled boluses of potentially toxic medication, has not been independently investigated. We performed this laboratory study to define the flow-rate accuracy, reliability, and profiles of various portable bolus-capable infusion pumps and varied several factors that may influence pump performance.MethodsUsing a computer/scale combination, 4 electronic pumps were tested with 1 and 2 sets of batteries over 100 hours. One elastomeric pump was tested with its flow-regulator at room temperature (20 degrees C to 24 degrees C), skin temperature (32 degrees C), and increased temperature (36 degrees C). The elastomeric pump was also tested by varying the height of the pump relative to the distal end of the catheter.ResultsInfusion rate accuracy differed significantly among the pumps, exhibiting flow rates within +/-15% of their expected rate for 29% to 100% of their infusion duration. Changing the batteries after 50 hours affected the profile of 1 of the 4 electronic pumps. For the elastomeric pump, an increase in temperature significantly increased the infusion rate. An increase or decrease in pump-to-scale height significantly increased or decreased the infusion rate, respectively.ConclusionsThese results suggest that factors such as flow-rate accuracy and consistency, infusion profile, and temperature sensitivity should be taken into consideration when choosing a portable infusion pump for local anesthetic administration.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.